INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT SHIFT SOLENOID VALVE SL3 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid valve makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SLT |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid valve makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE S4 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
Solenoid Connector (S4) - Solenoid Body (S4)
20°C (68°F)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid valve makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SR |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
Solenoid Connector (SR) - Solenoid Body (SR)
20°C (68°F)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid valve makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE DSL |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
Solenoid Connector (DSL) - Solenoid Body (DSL)
20°C (68°F)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid valve makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SL2 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid valve makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SL1 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid valve makes an operating sound.
