B1449/49 Rear Air Outlet Damper Control Servo Motor Circuit
Diagnostic trouble codes · Vehicles built from Jul 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
The rear outlet control servo motor sends pulse signals to indicate the damper position to the air conditioning amplifier. The air conditioning amplifier activates the motor (normal or reverse) based on these signals to move the rear outlet damper to the appropriate position, which controls the air outlet modes.- HINT:
- Confirm that there are no mechanical problems because this DTC can be set if either a damper link or damper is mechanically locked.
DTC No.
DTC Detection Condition
Trouble Area
B1449/49
Rear air outlet damper position does not change even if air conditioning amplifier operates rear air outlet damper control servo motor
- Rear air outlet control servo motor
- Rear air conditioning harness
- Wire harness between rear air conditioning harness and air conditioning amplifier
- Air conditioning amplifier
- Rear air outlet control servo motor
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AIR OUT PULSE-R) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
Data List / Air Conditioner: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Air Out Pulse-R
Rear air outlet control servo motor target pulse /
Min.: 0, Max.: 255
Rr FACE: 83 (pulse)
Rr B/L: 38 (pulse)
Rr FOOT: 7 (pulse)
-
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from PROBLEM SYMPTOMS TABLE)
B
OK (Checking from DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. CHECK HARNESS AND CONNECTOR (REAR AIR CONDITIONING HARNESS - AIR CONDITIONING AMPLIFIER) |
Disconnect the N11 rear air conditioning harness connector.

Disconnect the D34 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
N11-2 (RBUG) - D34-21 (RBUG)
Always
Below 1 Ω
N11-3 (RBUS) - D34-1 (RBUS)
Always
Below 1 Ω
N11-4 (RBBU) - D34-23 (RBBU)
Always
Below 1 Ω
D34-21 (RBUG) - Body ground
Always
10 kΩ or higher
D34-1 (RBUS) - Body ground
Always
10 kΩ or higher
D34-23 (RBBU) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 3. REPLACE REAR AIR OUTLET CONTROL SERVO MOTOR |
Replace the rear air outlet control servo motor.
| NEXT | |
| 4. CHECK DTC OUTPUT |
Clear the DTC (Click here).
Check for DTC (Click here).
- OK:
- DTC B1449/49 is not output.
|
|
||||
| OK | ||
| ||