Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)
Rear Blower Motor Circuit
Circuit diagnosis · Vehicles built Aug 2008 – Jun 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
The rear blower motor is operated by signals from the air conditioning amplifier. Rear blower motor speed signals are transmitted in accordance with changes in the duty ratio. WIRING DIAGRAM
INSPECTION PROCEDURE
1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (REAR BLOWER MOTOR)
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Active Test, and then check that the rear blower motor operates.
Active Test / Air Conditioner:
Tester Display
Test Part
Control Range
Diagnostic Note
R Blower Motor
Rear blower motor
Min.: 0, Max.: 31
-
Result:
Result
Proceed to
NG (blower motor does not operate)
A
NG (blower motor operates but does not change speed)
B
OK
C
B
C
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
A
2. INSPECT FUSE (RR CLR)
Remove the RR CLR H-fuse from the main body ECU.
Measure the resistance of the H-fuse.
Standard resistance:
Tester Connection
Condition
Specified Condition
RR CLR H-fuse
Always
Below 1 Ω
NG
OK
3. INSPECT REAR BLOWER MOTOR
Disconnect the N9 motor connector.
Connect the battery's positive (+) lead to terminal 2 and the negative (-) to terminal 1, then check that the rear blower motor operates smoothly.
OK:
The rear blower motor operates smoothly.
Measure the current of the connector.
Standard current:
Tester Connection
Condition
Specified Condition
N9-1 - N9-2
Rear blower motor operates
Below 13.5 A
NG
OK
4. CHECK HARNESS AND CONNECTOR (REAR BLOWER MOTOR CONTROL - BODY GROUND)
Disconnect the N10 rear motor control connector.
Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
Condition
Specified Condition
N10-6 (GND) - Body ground
Always
Below 1 Ω
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
5. CHECK HARNESS AND CONNECTOR (REAR BLOWER MOTOR CONTROL - BATTERY)
Disconnect the N10 rear motor control connector.
Measure the voltage according to the value(s) in the table below.
Standard voltage:
Tester Connection
Condition
Specified Condition
N10-1 (+B) - Body ground
Ignition switch on (IG)
11 to 14 V
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
6. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND)
Disconnect the D34 amplifier connector.
Measure the voltage according to the value(s) in the table below.
Standard voltage:
Tester Connection
Condition
Specified Condition
D34-22 (BLWH) - D34-20 (GND2)
Ignition switch on (IG) Blower switch OFF
4.5 to 5.5 V
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
7. CHECK AIR CONDITIONING AMPLIFIER
Remove the air conditioning amplifier with its connectors still connected.
Check the waveform of the amplifier connector.
OK:
Waveform is as shown in the illustration.
HINT:
The waveform varies with the blower level.
Item
Content
Tester Connection
BLWH (D34-22) - GND2 (D34-20)
Tool Setting
1 V/DIV., 500 μsec./DIV.
Condition
Ignition switch on (IG) Blower switch LO
NG
OK