2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

Rear Blower Motor Circuit

Circuit diagnosis · Vehicles built from Jul 2010

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

The rear blower motor is operated by signals from the air conditioning amplifier. Rear blower motor speed signals are transmitted in accordance with changes in the duty ratio.
E115031E07

WIRING DIAGRAM

E127601E08

INSPECTION PROCEDURE


1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (REAR BLOWER MOTOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Active Test, and then check that the rear blower motor operates.

    Active Test / Air Conditioner: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    R Blower Motor
    Rear blower motor
    Min.: 0, Max.: 31
    -

    Result:
    Result
    Proceed to
    NG (blower motor does not operate)
    A
    NG (blower motor operates but does not change speed)
    B
    OK
    C



B
Go to step 6

C
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)
A


2. INSPECT FUSE (RR CLR)
  1. Remove the RR CLR fuse from the main body ECU.

  1. Measure the resistance of the RR CLR fuse.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    RR CLR fuse
    Always
    Below 1 Ω



NG
REPLACE FUSE
OK


3. INSPECT REAR BLOWER MOTOR

  1. E153715E02
    Disconnect the N9 motor connector.

  1. Connect the battery's positive (+) lead to terminal 2 and the negative (-) to terminal 1, then check that the rear blower motor operates smoothly.

    OK:
    The rear blower motor operates smoothly.

  1. Measure the current of the connector.

    Standard current:
    Tester Connection
    Condition
    Specified Condition
    N9-1 - N9-2
    Rear blower motor operates
    Below 13.5 A



NG
REPLACE REAR BLOWER MOTOR (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (REAR BLOWER MOTOR CONTROL - BODY GROUND)

  1. E153716E04
    Disconnect the N10 rear motor control connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N10-6 (GND) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. CHECK HARNESS AND CONNECTOR (REAR BLOWER MOTOR CONTROL - BATTERY)

  1. E153716E05
    Disconnect the N10 rear motor control connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    N10-1 (+B) - Body ground
    Ignition switch on (IG)
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND)

  1. E153680E03
    Disconnect the D34 amplifier connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D34-22 (BLWH) - D34-20 (GND2)
    Ignition switch on (IG)
    Blower switch OFF
    4.5 to 5.5 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7. CHECK AIR CONDITIONING AMPLIFIER

  1. E127604E04
    Remove the air conditioning amplifier with its connectors still connected.

  1. Check the waveform of the amplifier connector.

    OK:
    Waveform is as shown in the illustration.

    HINT:
    The waveform varies with the blower level.

    Item
    Content
    Tester Connection
    BLWH (D34-22) - GND2 (D34-20)
    Tool Setting
    1 V/DIV., 500 μsec./DIV.
    Condition
    Ignition switch on (IG)
    Blower switch LO



NG
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
OK

REPLACE REAR BLOWER MOTOR (Click here)


← Rear Blower Motor Circuit (Aug 2008 – Jun 2010)IG Power Source Circuit (May 2007 – Jul 2008) →