INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT ENTRY LOCK SWITCH (for Driver Side) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
- for LHD:
Tester Connection
Condition
Specified Condition
z13-1 (TRG-) - z13-3 (TRG+)
Lock switch not pushed
10 kΩ or higher
z13-1 (TRG-) - z13-3 (TRG+)
Lock switch pushed
Below 1 Ω
- for RHD:
Tester Connection
Condition
Specified Condition
z15-1 (TRG-) - z15-3 (TRG+)
Lock switch not pushed
10 kΩ or higher
z15-1 (TRG-) - z15-3 (TRG+)
Lock switch pushed
Below 1 Ω
| INSPECT ENTRY LOCK SWITCH (for Front Passenger Side) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
- for LHD:
Tester Connection
Condition
Specified Condition
z15-1 (TRG-) - z15-3 (TRG+)
Lock switch not pushed
10 kΩ or higher
z15-1 (TRG-) - z15-3 (TRG+)
Lock switch pushed
Below 1 Ω
- for RHD:
Tester Connection
Condition
Specified Condition
z13-1 (TRG-) - z13-3 (TRG+)
Lock switch not pushed
10 kΩ or higher
z13-1 (TRG-) - z13-3 (TRG+)
Lock switch pushed
Below 1 Ω