Home › SECURITIES › THEFT DETERRENT › THEFT DETERRENT SYSTEM (w/ Smart Entry and Start System)
Security Horn Circuit
Circuit diagnosis · Vehicles built Aug 2008 – Jun 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
When the theft deterrent system is switched from the armed state to the alarm sounding state, the certification ECU (smart key ECU assembly) controls the security horn. WIRING DIAGRAM
INSPECTION PROCEDURE
1. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ENGINE ROOM JUNCTION BLOCK)
Disconnect the D35 ECU connector.
Connect a negative battery lead to terminal 20 (SH-) of the D35 ECU connector.
Check operation of the security horn.
OK:
Measurement Condition
Specified Condition
Battery negative (-) → D35-20 (SH-)
Horn sounds
NG
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
2. INSPECT SECURITY HORN ASSEMBLY
Remove the security horn assembly.
Connect a positive battery lead to terminal 1 of the security horn assembly, and a negative battery lead to the horn body.
Check operation of the horn.
OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 1
Horn sounds
Battery negative (-) → Horn body
NG
OK
3. CHECK HARNESS AND CONNECTOR (ENGINE ROOM JUNCTION BLOCK - SECURITY HORN ASSEMBLY)
Disconnect the 2A engine room junction block connector and A16 security horn assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
Condition
Specified Condition
2A-5 - A16-1
Always
Below 1 Ω
2A-5 - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
4. CHECK HARNESS AND CONNECTOR (BATTERY - ENGINE ROOM JUNCTION BLOCK)
Disconnect the 2G engine room junction block connector.
Measure the voltage on the junction block side according to the value(s) in the table below.
Standard voltage:
Tester Connection
Condition
Specified Condition
2G-1 - Body ground
Always
11 to 14 V
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
5. CHECK HARNESS AND CONNECTOR (ENGINE ROOM JUNCTION BLOCK - CERTIFICATION ECU)
Disconnect the 2D engine room junction block connector.
Disconnect the D35 ECU connector.
Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection
Condition
Specified Condition
2D-11 - D35-20 (SH-)
Always
Below 1 Ω
D35-20 (SH-) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE ENGINE ROOM JUNCTION BLOCK