INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT DUTY VACUUM SWITCHING VALVE (OPERATION) |
Check the operation of the duty vacuum switching valve when positive battery voltage is applied to its terminals.

- Positive battery voltage is not applied:
- The air from pipe G is flowing out through pipes E and H.
- Positive battery voltage is applied:
- The air from pipe F is flowing out through pipes E and H.
| INSPECT DUTY VACUUM SWITCHING VALVE (RESISTANCE) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
19 to 21 Ω