DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0712 | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic) |
|
| P0713 | Either of the following conditions is met (1-trip detection logic) (A) 15 minutes or more after the engine is started, ATF temperature sensor resistance is more than 156 kΩ for 0.5 sec. or more. (B) The condition (A) of "TYPICAL ENABLING CONDITIONS" for DTC P0711 is met and ATF temperature sensor resistance is more than 156 kΩ for 0.5 sec. or more. |
|
| Related DTCs | P0712: ATF temperature sensor/Range check (Low resistance) P0713: ATF temperature sensor/Range check (High resistance) |
| Required sensors/Components | ATF temperature sensor (TFT sensor) |
| Frequency of operation | Continuous |
| Duration | 0.5 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever these DTCs are not present. | None |
| The typical enabling condition is not available. | - |
| The monitor will run whenever this DTC is not present. | None |
| Time after engine start | 15 min. or more |
| TFT sensor resistance | Less than 79 Ω |
| TFT sensor resistance | More than 156 kΩ |
| TFT sensor | Atmospheric temperature to approx. 130°C (266°F) |

| READ DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect Techstream to the DLC3.
Turn the ignition switch on (IG).
Turn on the tester.
Select the item "Powertrain / Engine and ECT / Data List".
According to the display on the tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 1 | ATF Temp. Sensor Value/ min.: -40°C (-40°F) max.: 215°C (419°F) | After Stall Test: Approx. 80°C (176°F) Equal to ambient temperature when cold soak | If the value is "-40°C (-40°F)" or "215°C (419°F)", ATF temp. sensor circuit is opened or shorted. |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (THO) - 7 (E2) | Always | 79 Ω to 156 kΩ |
| 1 (THO) - Body ground | Always | 10 kΩ or higher |
| 7 (E2) - Body ground | Always | ↑ |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transaxle.
Disconnect the ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B2-24 (THO1) - B1-28 (E2) | Always | 79 Ω to 156 kΩ |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B2-24 (THO1) - Body ground | Always | 10 kΩ or higher |
| B1-28 (E2) - Body ground |
|
| ||||
| OK | ||
| ||