DTC P0351 Ignition Coil "A" Primary / Secondary Circuit |
DTC P0352 Ignition Coil "B" Primary / Secondary Circuit |
DTC P0353 Ignition Coil "C" Primary / Secondary Circuit |
DTC P0354 Ignition Coil "D" Primary / Secondary Circuit |
DTC P0355 Ignition Coil "E" Primary / Secondary Circuit |
DTC P0356 Ignition Coil "F" Primary / Secondary Circuit |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0351 P0352 P0353 P0354 P0355 P0356 | No IGF signal to ECM while engine is running (1 trip detection logic) |
|

| Item | Content |
| Terminals | CH1: IGT1, IGT2, IGT3, IGT4, IGT5, IGT6 - E1 CH2: IGF1 - E1 |
| Equipment Settings | 2 V/DIV., 20 ms./DIV. |
| Conditions | Cranking or idling |

| Related DTCs | P0351: Igniter (Cylinder 1) malfunction P0352: Igniter (Cylinder 2) malfunction P0353: Igniter (Cylinder 3) malfunction P0354: Igniter (Cylinder 4) malfunction P0355: Igniter (Cylinder 5) malfunction P0356: Igniter (Cylinder 6) malfunction |
| Required Sensors / Components (Main) | Igniter (Cylinder 1 to 6) |
| Required Sensors / Components (Related) | Crankshaft position sensor |
| Frequency of Operation | Continuous |
| Duration | 0.256 seconds and 5 sparks |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Either of the following conditions met | Condition 1 or 2 |
| 1. All of the following conditions are met: | Condition (a) and (b) |
| (a) Engine RPM | 500 rpm or less |
| (b) Battery voltage | 6 V or more |
| 2. All of the following conditions are met: | Condition (c) and (d) |
| (c) Engine RPM | More than 500 rpm |
| (d) Battery voltage | 10 V or more |
| Ignition signal fail count | More than 2 times |
| Ignition signal fail count is on the right | No ignition confirmation signal from igniter. |
| IGF signal | Igniter transmits IGF signal when it receives IGT signal from ECM |



| 1.CHECK DTC OUTPUT |
Connect the Techstream to the DLC3.
Turn the ignition switch on (IG).
Turn the tester on.
Enter the following menu items: Powertrain / Engine and ECT / DTC.
Read the DTC.
| Result | Proceed to |
| DTC P0351, P0352, P0353. P0354 or P0356 is output | A |
| P0351, P0352, P0353, P0354 and P0356 are output | B |
|
| ||||
| A | |
| 2.CHECK WHETHER DTC OUTPUT RECURS (DTC P0351, P0352, P0353, P0354, P0355 OR P0356) |
Connect the Techstream to the DLC3.
Turn the ignition switch on (IG).
Turn the tester on.
Clear the DTCs (Click here).
Shuffle arrangement of the ignition coils with igniters (among No. 1 to No. 4 cylinders).
Perform a simulation test.
Check the DTCs displayed on the tester.
| Result | Proceed to |
| Same DTC output | A |
| Different ignition coil DTC output | B |
|
| ||||
| A | |
| 3.CHECK IGNITION COIL ASSEMBLY (POWER SOURCE) |
![]() |
Disconnect the ignition coil connector of malfunctioning cylinder.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (+B) - Body ground | Ignition switch on (IG) | 9 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 4 (GND) - Body ground | Always | Below 1 Ω |
Reconnect the ignition coil connector.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM) |
![]() |
Disconnect the ignition coil connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B30-2 (IGF) - B1-24 (IGF1) | Always | Below 1 Ω |
| B31-2 (IGF) - B1-24 (IGF1) | Always | Below 1 Ω |
| B32-2 (IGF) - B1-24 (IGF1) | Always | Below 1 Ω |
| B33-2 (IGF) - B1-24 (IGF1) | Always | Below 1 Ω |
| B34-2 (IGF) - B1-24 (IGF1) | Always | Below 1 Ω |
| B35-2 (IGF) - B1-24 (IGF1) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| B30-2 (IGF) or B1-24 (IGF1) - Body ground | Always | 10 kΩ or higher |
| B31-2 (IGF) or B1-24 (IGF1) - Body ground | Always | 10 kΩ or higher |
| B32-2 (IGF) or B1-24 (IGF1) - Body ground | Always | 10 kΩ or higher |
| B33-2 (IGF) or B1-24 (IGF1) - Body ground | Always | 10 kΩ or higher |
| B34-2 (IGF) or B1-24 (IGF1) - Body ground | Always | 10 kΩ or higher |
| B35-2 (IGF) or B1-24 (IGF1) - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the ignition coil connector.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM) |
![]() |
Disconnect the ignition coil connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B30-3 (IGT1) - B1-8 (IGT1) | Always | Below 1 Ω |
| B31-3 (IGT2) - B1-9 (IGT2) | Always | Below 1 Ω |
| B32-3 (IGT3) - B1-10 (IGT3) | Always | Below 1 Ω |
| B33-3 (IGT4) - B1-11 (IGT4) | Always | Below 1 Ω |
| B34-3 (IGT5) - B1-12 (IGT5) | Always | Below 1 Ω |
| B35-3 (IGT6) - B1-13 (IGT6) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| B30-3 (IGT1) or B1-8 (IGT1) - Body ground | Always | 10 kΩ or higher |
| B31-3 (IGT2) or B1-9 (IGT2) - Body ground | Always | 10 kΩ or higher |
| B32-3 (IGT3) or B1-10 (IGT3) - Body ground | Always | 10 kΩ or higher |
| B33-3 (IGT4) or B1-11 (IGT4) - Body ground | Always | 10 kΩ or higher |
| B34-3 (IGT5) or B1-12 (IGT5) - Body ground | Always | 10 kΩ or higher |
| B35-3 (IGT6) or B1-13 (IGT6) - Body ground | Always | 10 kΩ or higher |
Reconnect the ignition coil connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 6.INSPECT FUSE (INJ NO. 1 FUSE) |
![]() |
Remove the INJ No. 1 fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| INJ No. 1 fuse | Always | Below 1 Ω |
Reinstall the INJ No. 1 fuse.
|
| ||||
| OK | |
| 7.INSPECT RELAY (IG2 RELAY) |
![]() |
Remove the IG2 relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | When no battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | When battery voltage applied to terminals 1 and 2 | Below 1 Ω |
Reinstall the IG2 relay.
|
| ||||
| OK | ||
| ||