DTC P0717 Turbine Speed Sensor Circuit No Signal |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0717 | ECM detects conditions (a), (b) and (c) continuously for 5 sec. or more: (1-trip detection logic) (a) Vehicle speed: 50 km/h (31 mph) or more (b) Park/neutral position switch (NSW (STAR) and R) is OFF (c) Speed sensor (NT): less than 300 rpm |
|

| Terminal | NT+ - NT- |
| Tool setting | 5 V/DIV, 0.5 ms/DIV |
| Vehicle condition | Vehicle speed 20 km/h (12 mph) |
| Related DTCs | P0717: Speed sensor (NT)/Verify pulse input |
| Required sensors/Components | Speed sensor (NT), Speed sensor (NC) |
| Frequency of operation | Continuous |
| Duration | 5 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. (Not circuit malfunction) | P0746, P0748 (Shift solenoid valve SL1 circuit) P0776, P0778 (Shift solenoid valve SL2 circuit) P0796, P0798 (Shift solenoid valve SL3 circuit) P0766, P0982, P0983 (Shift solenoid valve S4 circuit) P0985, P0986 (Shift solenoid valve SR circuit) |
| Shift change | Shift change is completed and before starting next shift change operation |
| ECM selected gear | 2nd, 3rd, 4th or 5th |
| Output shaft rpm | 1000 rpm or more |
| NSW (STAR) switch | OFF |
| R switch | OFF |
| Engine | Running |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Sensor signal rpm | Less than 300 rpm |
| Speed sensor (NT) | Turbine speed is equal to engine speed with lock-up ON |

| 1.INSPECT SPEED SENSOR INSTALLATION |
![]() |
Check the speed sensor installation.
|
| ||||
| OK | |
| 2.INSPECT SPEED SENSOR (NT) |
![]() |
Disconnect the speed sensor connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 560 to 680 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR - ECM) |
![]() |
Connect the speed sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B2-35 (NT+) - B2-27 (NT-) | 20°C (68°F) | 560 to 680 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B2-35 (NT+) - Body ground | Always | 10 kΩ or higher |
| B2-27 (NT-) - Body ground |
|
| ||||
| OK | ||
| ||