DTC    P2716    Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and the vehicle speed sensor. The ECM adjusts the duty cycle of the SLT solenoid valve to control hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.
(*): Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then
Duty Ratio=A/(A + B) x 100(%)

DTC No.
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detecting logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM
C114295E03

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

MONITOR STRATEGY


Related DTCs
P2716: Shift solenoid valve SLT/Range check
Required sensors/Components
Shift solenoid valve SLT
Frequency of operation
Continuous
Duration
1 sec.
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever this DTC is not present.
None
Solenoid current cut status
Not cut
Battery voltage
11 V or more
Ignition switch
ON
Starter
OFF
CPU commanded duty ratio to SLT
19% or more

TYPICAL MALFUNCTION THRESHOLDS


Solenoid status from MIC
Fail (Open or short)

COMPONENT OPERATING RANGE


Shift solenoid valve SLT
Resistance: 5.0 to 5.6 Ω at 20°C (68°F)

WIRING DIAGRAM


G031770E42


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SLT)


    C113969E66
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (SLT+) - 8 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    2 (SLT+) - Body ground
    Always
    10 kΩ or higher
    8 (SLT-) - Body ground
    Always
    ↑



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C168530E30
  1. Connect the transmission wire connector to the transaxle.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B2-13 (SLT+) - B2-12 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    B2-13 (SLT+) - Body ground
    Always
    10 kΩ or higher
    B2-12 (SLT-) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (for 2GR-FE) (Click here)  

3.INSPECT SHIFT SOLENOID VALVE (SLT)


    G020767E92
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance :
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE (SLT) (Click here)
OK