Home › TRANSMISSION · U151F AUTOMATIC TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

DTC    P0778    Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, S4 and SR which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).

DTC No.
DTC Detection Condition
Trouble Area
P0778
ECM checks for an open or short circuit in shift solenoid valves SL2 (1-trip detection logic)
Hybrid IC for solenoid indicates fail.
  1. Open or short in shift solenoid valve SL2 circuit
  2. Shift solenoid valve SL2
  3. ECM

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL, and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit.) (Click here).

MONITOR STRATEGY


Related DTCs
P0778: Shift solenoid valve SL2/Range check
Required sensors/Components
Shift solenoid valve SL2
Frequency of operation
Continuous
Duration
1 sec.
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever this DTC is not present.
None
Solenoid current cut status
Not cut
Battery voltage
11 V or more
Ignition switch
ON
Starter
OFF
CPU commanded duty ratio to SL2
19% or more

TYPICAL MALFUNCTION THRESHOLDS


Solenoid status from IC
Fail (Open or short)

COMPONENT OPERATING RANGE


Output signal duty
Less than 100%

WIRING DIAGRAM


G031765E67


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SL2)


    C113969E61
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    5 (SL2+) - 12 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    5 (SL2+) - Body ground
    Always
    10 kΩ or higher
    12 (SL2-) - Body ground
    Always
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C168530E25
  1. Connect the transmission wire connector to the transaxle.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B2-15 (SL2+) - B2-14 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    B2-15 (SL2+) - Body ground
    Always
    10 kΩ or higher
    B2-14 (SL2-) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (for 2GR-FE) (Click here)  

3.INSPECT SHIFT SOLENOID VALVE (SL2)


    G020767E89
  1. Remove the shift solenoid valve SL2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE (SL2) (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)