DTC P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR) |
DTC P0986 Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0985 | ECM detects short in solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic) |
|
| P0986 | ECM detects open in solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic) |
|
| Related DTCs | P0985: Shift solenoid valve SR/Range check (Low resistance) P0986: Shift solenoid valve SR/Range check (High resistance) |
| Required sensors/Components | Shift solenoid valve SR |
| Frequency of operation | Continuous |
| Duration | 0.064 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever this DTC is not present. | None |
| Shift solenoid valve SR | ON |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| The monitor will run whenever this DTC is not present. | None |
| Shift solenoid valve SR | OFF |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Shift solenoid valve SR resistance | 8 Ω or less |
| Shift solenoid valve SR resistance | 100 kΩ or more |
| Shift solenoid valve SR | Resistance: 11 to 15 Ω at 20°C (68°F) |

| 1.INSPECT TRANSMISSION WIRE (SR) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 9 (SR) - Body ground | 20°C (68°F) | 11 to 15 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B2-9 (SR) - Body ground | 20°C (68°F) | 11 to 15 Ω |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE (SR) |
![]() |
Remove the shift solenoid valve SR.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Solenoid Connector (SR) - Solenoid Body (SR) | 20°C (68°F) | 11 to 15 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
|
| ||||
| OK | ||
| ||