Home › ENGINE › 2GR-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0031    Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1)

DTC    P0032    Oxygen (A/F) Sensor Heater Control Circuit High (Bank 1 Sensor 1)

DTC    P0051    Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 2 Sensor 1)

DTC    P0052    Oxygen (A/F) Sensor Heater Control Circuit High (Bank 2 Sensor 1)

for Preparation Click here

HINT:
  1. Although the DTC titles say the oxygen sensor, these DTCs relate to the air fuel ratio sensor.
  2. Sensor 1 refers to the sensor mounted in front of the three-way catalytic converter and located near the engine assembly.


DESCRIPTION

Refer to DTC P2195 .

HINT:
  1. When any of these DTCs are set, the ECM enters fail-safe mode. The ECM turns off the air fuel ratio sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off.
  2. The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The air fuel ratio sensor heater circuit uses a relay on the +B side of the circuit.


A133850E10


DTC No.
DTC Detection Condition
Trouble Area
P0031
P0051
Air fuel ratio sensor heater current less than 0.8 A (1 trip detection logic)
  1. Open in air fuel ratio sensor heater circuit
  2. Air fuel ratio sensor heater (Bank 1, 2 Sensor 1)
  3. A/F relay
  4. ECM
P0032
P0052
Air-Fuel Ratio (A/F) sensor heater current fail
(1 trip detection logic)
  1. Short in air fuel ratio sensor heater circuit
  2. Air fuel ratio sensor heater (Bank 1, 2 Sensor 1)
  3. A/F relay
  4. ECM

HINT:
  1. Bank 1 refers to the bank that includes cylinder No. 1.
  2. Bank 2 refers to the bank that does not include cylinder No. 1.
  3. Sensor 1 refers to the closest sensor to the engine assembly.
  4. Sensor 2 refers to the furthest sensor away from the engine assembly.


MONITOR DESCRIPTION

The ECM uses information from the air fuel ratio sensor to regulate the air-fuel ratio and keep it close to the stoichiometric level. This maximizes the ability of the three-way catalytic converter to purify the exhaust gas.
The air fuel ratio sensor detects oxygen levels in the exhaust gas and transmits the information to the ECM. The inner surface of the sensor element is exposed to the outside air. The outer surface of the sensor element is exposed to the exhaust gas. The sensor element is made of platinum coated zirconia and includes an integrated heating element.
The zirconia element generates small voltage when there is a large difference in the oxygen concentrations between the exhaust gas and outside air. The platinum coating amplifies this voltage generation.
The air fuel ratio sensor is more efficient when heated. When the exhaust gas temperature is low, the sensor cannot generate useful voltage signals without supplementary heating. The ECM regulates the supplementary heating using a duty-cycle approach to adjust the average current in the sensor heater element. If the heater current is outside the normal range, the signal transmitted by the air fuel ratio sensor will be inaccurate, as a result, the ECM will be unable to regulate air-fuel ratio properly.
When the current in the air fuel ratio sensor heater is outside the normal operating range, the ECM interprets this as a malfunction in the sensor heater and sets a DTC.
Example:
  1. The ECM sets DTC P0032 or P0052 when the current in the air fuel ratio sensor heater is fail. Conversely, when the heater current is less than 0.8 A, DTC P0031 or P0051 is set.

MONITOR STRATEGY


Related DTCs
P0031: Air fuel ratio sensor heater (Bank 1) range check (Low current)
P0032: Air fuel ratio sensor heater (Bank 1) range check (High current)
P0051: Air fuel ratio sensor heater (Bank 2) range check (Low current)
P0052: Air fuel ratio sensor heater (Bank 2) range check (High current)
Required sensors / components (Main)
Air fuel ratio sensor heater
Required sensors / components (Related)
-
Frequency of operation
Continuous
Duration
10 seconds
MIL operation
Immediate
Sequence operation
None

TYPICAL ENABLING CONDITIONS


All: 
The monitor will run whenever these DTCs are not present
None

P0031 and P0051: 
Battery voltage
10.5 V or more
Heater ON duty ratio
50% or more
Time after engine starts
10 seconds or more

P0032 and P0052: 
Time after engine starts
10 seconds or more

TYPICAL MALFUNCTION THRESHOLDS


P0031 and P0051: 
Heater current
Less than 0.8 A

P0032 and P0052: 
Hybrid IC high current limit port
Fail

COMPONENT OPERATING RANGE


Air fuel ratio sensor heater current
0.8 A or more

MONITOR RESULT

Refer to CHECKING MONITOR STATUS (Click here).

WIRING DIAGRAM

Refer to DTC P2195 .

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE)


    A126269E40
  1. Disconnect the air fuel ratio sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    1 (HA1A) - 2 (+B)
    20°C (68°F)
    1.8 to 3.4 Ω
    1 (HA1A) - 4 (A1A-)
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    1 (HA2A) - 2 (+B)
    20°C (68°F)
    1.8 to 3.4 Ω
    1 (HA2A) - 4 (A2A-)
    Always
    10 kΩ or higher

  1. Reconnect the air fuel ratio sensor connector.



NG
REPLACE AIR FUEL RATIO SENSOR (Click here)
OK


2.CHECK TERMINAL VOLTAGE (+B OF AIR FUEL RATIO SENSOR)


    A168194E04
  1. Disconnect the air fuel ratio sensor connector.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Bank 1:
    Tester Connection
    Switch Condition
    Specified Condition
    B20-2 (+B) - Body ground
    Ignition switch on (IG)
    9 to 14 V
    Bank 2:
    Tester Connection
    Switch Condition
    Specified Condition
    B19-2 (+B) - Body ground
    Ignition switch on (IG)
    9 to 14 V

  1. Reconnect the air fuel ratio sensor connector.



NG
Go to step 5
OK


3.CHECK HARNESS AND CONNECTOR (AIR FUEL RATIO SENSOR RELAY - ECM)


    A168195E04
  1. Disconnect the air fuel ratio sensor connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B20-1 (HA1A) - B2-2 (HA1A)
    Always
    Below 1 Ω
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B19-1 (HA2A) - B2-1 (HA2A)
    Always
    Below 1 Ω


    Standard resistance (Check for short):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B20-1 (HA1A) or B2-2 (HA1A) - Body ground
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B19-1 (HA2A) or B2-1 (HA2A) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the air fuel ratio sensor connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (AIR FUEL RATIO SENSOR - ECM)
OK


4.CHECK WHETHER DTC OUTPUT RECURS
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch on (IG).

  1. Turn the tester on.

  1. Clear the DTCs (Click here).

  1. Start the engine.

  1. Allow the engine to idle for 1 minute or more.

  1. Select the following menu items: Powertrain / Engine and ECT / Trouble Code.

  1. Read the DTCs.

    Result:

    Display (DTC Output)
    Proceed to
    No output
    A
    P0031, P0032, P0051 and/or P0052
    B



B
REPLACE ECM (Click here)
A

CHECK FOR INTERMITTENT PROBLEMS (Click here)  

5.INSPECT FUSE (A/F FUSE)


    A168235E01
  1. Remove the A/F fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A/F fuse
    Always
    Below 1 Ω

  1. Reinstall the A/F fuse.



NG
REPLACE FUSE (A/F FUSE)
OK


6.INSPECT ENGINE ROOM JUNCTION BLOCK ASSEMBLY (A/F RELAY)
  1. Inspect the A/F relay (Click here).



NG
REPLACE ENGINE ROOM JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (A/F FUSE - AIR FUEL RATIO SENSOR)