BRAKE ACTUATOR > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE V-BANK COVER SUB-ASSEMBLY |
![]() |
Hold the front of the V-bank cover and raise it to disengage the 2 clips on the front of the V-bank cover sub-assembly. Continue rising the V-bank cover sub-assembly to disengage the clip on the rear of the V-bank cover sub-assembly and remove the cover.
| 3. REMOVE BRAKE ACTUATOR WITH BRACKET |
![]() |
Separate the relay box.
![]() |
Remove the nut, bolt and separate the suction hose bracket from the brake actuator bracket assembly.
![]() |
Separate the No. 1 cooler refrigerant suction tube from the 2 clamps, and then place the No. 1 cooler refrigerant suction tube next to the clamps.
![]() |
Release the lock lever and disconnect the brake actuator connector.
![]() |
Using a union nut wrench (10 mm and 12 mm), disconnect the 6 brake lines from the brake actuator with bracket.
![]() |
Use tags or make a memo to identify the places to reconnect.
![]() |
Remove the 3 bolts and brake actuator with bracket from the body.
| 4. REMOVE BRAKE ACTUATOR |
![]() |
Remove the piping clamp.
![]() |
Remove the 3 bolts and the brake actuator from the brake actuator bracket assembly.