CAN COMMUNICATION SYSTEM > Yaw Rate Sensor Communication Stop Mode |
| Detection Item | Symptom | Trouble Area |
| Yaw Rate Sensor Communication Stop Mode |
|
|

| 1.CHECK FOR OPEN IN CAN BUS WIRE (YAW RATE SENSOR BRANCH WIRE) |
Turn the power switch off.
Disconnect the yaw rate sensor connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O6-3 (CANH) - O6-2 (CANL) | Power switch off | 54 to 69 Ω |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (IG, GND) |
Disconnect the yaw rate sensor connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O6-1 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O6-4 (IG) - Body ground | Power switch on (IG) | 10 to 14 V |
|
| ||||
| OK | ||
| ||