Home › HYBRID SYSTEM ยท P310 › HYBRID VEHICLE CONTROL › FRONT CIRCUIT BREAKER SENSOR

FRONT CIRCUIT BREAKER SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL NO. 1 CIRCUIT BREAKER SENSOR


    A181831
  1. Install the No. 1 circuit breaker sensor with the 2 bolts to the inverter with converter assembly.

    Torque:
    8.0 N*m{ 82 kgf*cm , 70 in.*lbf }



    A177454
  1. Connect the connector to the No. 1 circuit breaker sensor.

  1. Connect the clamp.



    A173814
  1. Install the bracket with the bolt.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }



2. INSTALL AIR CLEANER CAP SUB-ASSEMBLY
  1. Install the air cleaner filter element to the air cleaner case.



    A175875
  1. Install the 2 bolts, 4 clamps and air cleaner cap sub-assembly.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }



3. INSTALL COOL AIR INTAKE DUCT SEAL
  1. Install the cool air intake duct seal with the 11 clips.



4. INSTALL NO. 2 ENGINE ROOM SIDE COVER LH


    A173813
  1. Fit the clips and install the No. 2 engine room side cover LH.

    NOTICE:
    1. Be sure to engage the clips securely.
    2. Do not apply excessive force or do not hit the cover to engage the clips. This may cause the cover to break.



5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).