DTC P0A1B-788 Drive Motor "A" Control Module |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A1B | 788 | Error in reset signal from the power source IC |
|
| Related DTCs | P0A1B (INF 788): Reset from power IC |
| Required sensors / components | Motor Generator control ECU (MG ECU) |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| Motor Generator control ECU (MG ECU) | Internal error |
| Motor Generator control ECU (MG ECU) | DTC P0A1B (INF 788) is not detected |

| 1.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
![]() |
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (IGCT RELAY - MG ECU) |
Check that the service plug grip is not installed.
Remove the IGCT relay from the engine room relay block.
Disconnect connector A42 from the MG ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A42-7 (+B) - IGCT relay terminal 5 | Power switch off | Below 1 Ω |
| A42-4 (+B2) - IGCT relay terminal 5 | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A42-7 (+B) or A42-4 (+B2) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT MG ECU (+B VOLTAGE) |
![]() |
Check that the service plug grip is not installed.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A42-7 (+B) - Body ground | Power switch on (IG) | 10 V or more |
| A42-4 (+B2) - Body ground | Power switch on (IG) | 10 V or more |
|
| ||||
| OK | ||
| ||