DTC P0A60-288 Drive Motor "A" Phase V Current |
DTC P0A60-289 Drive Motor "A" Phase V Current |
DTC P0A60-290 Drive Motor "A" Phase V Current |
DTC P0A60-292 Drive Motor "A" Phase V Current |
DTC P0A60-294 Drive Motor "A" Phase V Current |
DTC P0A60-501 Drive Motor "A" Phase V Current |
DTC P0A63-296 Drive Motor "A" Phase W Current |
DTC P0A63-297 Drive Motor "A" Phase W Current |
DTC P0A63-298 Drive Motor "A" Phase W Current |
DTC P0A63-300 Drive Motor "A" Phase W Current |
DTC P0A63-302 Drive Motor "A" Phase W Current |
DTC P0A63-502 Drive Motor "A" Phase W Current |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A60 | 288 | Malfunction in the motor inverter current sensor (phase V sub sensor) |
|
| 289 | Open in the motor inverter current sensor (phase V sub sensor) circuit | ||
| 290 | Malfunction in the motor inverter current sensor (phase V main sensor) | ||
| 292 | Open in the motor inverter current sensor (phase V main sensor) circuit | ||
| 294 | Performance problem of the motor inverter current sensor phase V | ||
| 501 | Malfunction in the motor inverter current sensor (phase V main and sub sensors offset) | ||
| P0A63 | 296 | Malfunction in the motor inverter current sensor (phase W sub sensor) | |
| 297 | Open in the motor inverter current sensor (phase W sub sensor) circuit | ||
| 298 | Malfunction in the motor inverter current sensor (phase W main sensor) | ||
| 300 | Open in the motor inverter current sensor (phase W main sensor) circuit | ||
| 302 | Performance problem of the motor inverter current sensor phase W | ||
| 502 | Malfunction in the motor inverter current sensor (phase W main and sub sensors offset) |
| Related DTCs | P0A60 (INF 288): Motor inverter current sensor / Phase V, sub sensor / Out of range P0A60 (INF 289): Motor inverter current sensor / Phase V, sub sensor / Open circuit P0A60 (INF 290): Motor inverter current sensor / Phase V, main sensor / Out of range P0A60 (INF 292): Motor inverter current sensor / Phase V, main sensor / Open circuit P0A60 (INF 294): Motor inverter current sensor / Phase V deviation / Short to GND P0A60 (INF 501): Motor inverter current sensor / Offset malfunction P0A63 (INF 296): Motor inverter current sensor / Phase W, sub sensor / Out of range P0A63 (INF 297): Motor inverter current sensor / Phase W, sub sensor / Open circuit P0A63 (INF 298): Motor inverter current sensor / Phase W, main sensor / Out of range P0A63 (INF 300): Motor inverter current sensor / Phase W, main sensor / Open circuit P0A63 (INF 302): Motor inverter current sensor / Phase W deviation / Short to GND P0A63 (INF 502): Motor inverter current sensor / Offset malfunction |
| Required sensors / components | Motor inverter current sensor, motor resolver |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Motor inverter current sensor | DTC P0A60 (INF 288/289/290/292/294/501) is not detected |
| Motor inverter current sensor | DTC P0A63 (INF 296/297/298/300/302/502) is not detected |
| 1.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | ||
| ||