Home › HYBRID SYSTEM ยท P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A72-326    Generator Phase V Current

DTC    P0A72-327    Generator Phase V Current

DTC    P0A72-328    Generator Phase V Current

DTC    P0A72-330    Generator Phase V Current

DTC    P0A72-333    Generator Phase V Current

DTC    P0A72-515    Generator Phase V Current

DTC    P0A75-334    Generator Phase W Current

DTC    P0A75-335    Generator Phase W Current

DTC    P0A75-336    Generator Phase W Current

DTC    P0A75-338    Generator Phase W Current

DTC    P0A75-341    Generator Phase W Current

DTC    P0A75-516    Generator Phase W Current

for Preparation Click here


DESCRIPTION

The MG ECU monitors the inverter current sensor. These DTCs are for malfunctions in the sensor lines and not for malfunctions in the high-voltage lines.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A72
326
Malfunction in the generator inverter current sensor (phase V sub sensor)
  1. Inverter with converter assembly
327
Open in the generator inverter current sensor (phase V sub sensor) circuit
328
Malfunction in the generator inverter current sensor (phase V main sensor)
330
Open in the generator inverter current sensor (phase V main sensor) circuit
333
Performance problem of the generator inverter current sensor phase V
515
Malfunction in the generator inverter current sensor (phase V main and sub sensors offset)
P0A75
334
Malfunction in the generator inverter current sensor (phase W sub sensor)
335
Open in the generator inverter current sensor (phase W sub sensor) circuit
336
Malfunction in the generator inverter current sensor (phase W main sensor)
338
Open in the generator inverter current sensor (phase W main sensor) circuit
341
Performance problem of the generator inverter current sensor phase W
516
Malfunction in the generator inverter current sensor (phase W main and sub sensors offset)

MONITOR DESCRIPTION

The MG ECU monitors the generator inverter current sensor. If the hybrid vehicle control ECU detects a fault, it will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A72 (INF 326): Generator inverter current sensor / Phase V, sub sensor / Out of range
P0A72 (INF 327): Generator inverter current sensor / Phase V, sub sensor / Open circuit
P0A72 (INF 328): Generator inverter current sensor / Phase V, main sensor / Out of range
P0A72 (INF 330): Generator inverter current sensor / Phase V, main sensor / Open circuit
P0A72 (INF 333): Generator inverter current sensor / Phase V deviation / Short to GND
P0A72 (INF 515): Generator inverter current sensor / Offset malfunction
P0A75 (INF 334): Generator inverter current sensor / Phase W, sub sensor / Out of range
P0A75 (INF 335): Generator inverter current sensor / Phase W, sub sensor / Open circuit
P0A75 (INF 336): Generator inverter current sensor / Phase W, main sensor / Out of range
P0A75 (INF 338): Generator inverter current sensor / Phase W, main sensor / Open circuit
P0A75 (INF 341): Generator inverter current sensor / Phase W deviation / Short to GND
P0A75 (INF 516): Generator inverter current sensor / Offset malfunction
Required sensors / components
Generator inverter current sensor, Generator resolver
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


P0A72 (INF 326/327/328/330/333/515) 
Generator inverter current sensor
DTC P0A72 (INF 326/327/328/330/333/515) is not detected

P0A75 (INF 334/335/336/338/341/516) 
Generator inverter current sensor
DTC P0A75 (INF 334/335/336/338/341/516) is not detected

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)