DTC P0A78-278 Drive Motor "A" Inverter Performance |
DTC P0A78-280 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 278 | Short to +B in the motor inverter stop (OVH) signal line | Inverter with converter assembly (MG ECU) |
| 280 | Open or short to GND in the motor inverter stop (OVH) signal line |
| Related DTCs | P0A78 (INF 278): Motor inverter / OVH malfunction (short to +B) P0A78 (INF 280): Motor inverter / OVH malfunction (short to GND and disconnection) |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| Overvoltage signal circuit | Open or short |
| Motor inverter | DTC P0A78 (INF 278/280) is not detected |
| 1.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | ||
| ||