DTC P0A7A-342 Generator Inverter Performance |
DTC P0A7A-343 Generator Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A7A | 342 | Open or short to +B in generator gate shutdown (GSDN) signal line | Inverter with converter assembly (MG ECU) |
| 343 | Short to GND in generator gate shutdown (GSDN) signal line |
| Related DTCs | P0A7A (INF 342): Generator inverter / Generator gate shutdown signal malfunction (short to +B or open circuit) P0A7A (INF 343): Generator inverter / Generator gate shutdown signal malfunction (short to GND) |
| Required sensors / components | Generator inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| Generator gate shutdown signal circuit | Open or short |
| Generator inverter | DTC P0A7A (INF 342/343) is not detected |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A7A-342 or P0A7A-343 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P3232-749 | Open or Short to B+ Blocking of HV Gate Connection |
| P3233-750 | Short to B+ in Blocking of HV Gate Connection |
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | ||
| ||