DTC P0A94-547 DC / DC Converter Performance |
DTC P0A94-548 DC / DC Converter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A94 | 547 | Boost converter overvoltage signal detection (overvoltage by MG ECU malfunction) |
|
| 548 | Boost converter overvoltage signal detection (overvoltage by inverter malfunction) |
| Related DTCs | P0A94 (INF 547/548): OVL detection overvoltage |
| Required sensors / components | Boost converter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Boost converter | Overvoltage |
| Boost converter | DTC P0A94 (INF 547/548) is not detected |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A94-547 or 548 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A78-266, 280 | Drive Motor "A" Inverter Performance |
| P0A94-558, 559, 588, 589 | DC / DC Converter Performance |
| P0A95-123 | High Voltage Fuse |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P3004-803 | Power Cable Malfunction |
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of all MG ECU connectors.
|
| ||||
| OK | |
| 3.INSPECT HV RELAY ASSEMBLY (SMR2) |
Check that the service plug grip is not installed.
Remove the HV relay assembly from the vehicle (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z30-1 - j2-1 | Power switch off (Auxiliary battery voltage is applied between terminals z20-1 (CON2) and z20-4 (GND)) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z20-1 (CON2) - z20-4 (GND) | Power switch off (at -31 to 176°F (-35 to 80°C)) | 20 to 60 Ω |
|
| ||||
| OK | |
| 4.INSPECT HV RELAY ASSEMBLY (SMR3) |
Check that the service plug grip is not installed.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z31-1 - j3-1 | Power switch off (Auxiliary battery voltage is applied between terminals z20-2 (CON3) and z20-4 (GND)) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z20-2 (CON3) - z20-4 (GND) | Power switch off (at -31 to 176°F (-35 to 80°C)) | 20 to 60 Ω |
|
| ||||