Home › HYBRID SYSTEM ยท P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A94-442    DC / DC Converter Performance

for Preparation Click here


DESCRIPTION

The boost converter boosts the 288 V DC from the HV battery to a maximum of approximately 650 V DC. The inverter converts the voltage that has been boosted by the boost converter into alternating current, which is used for driving MG2, MG1, and MGR. When MG2, MG1, and MGR operate as a generator, the alternating current that is created is converted into direct current by the inverter. Then the boost converter drops this voltage to direct-current of approximately 288 V in order to charge the HV battery.

A105188E06

The MG ECU uses a voltage sensor (VL) that is built into the boost converter to detect the high voltage before it is boosted. It also uses a voltage sensor (VH) that is built into the inverter to detect the high voltage after it is boosted. Based on the voltage before and after it is boosted, the MG ECU controls the operation of the boost converter to boost the voltage to the target voltage.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A94
442
Abnormal voltage execution value
Inverter with converter assembly (MG ECU)

MONITOR DESCRIPTION

If the difference between the requested boost converter (inverter with converter assembly) voltage and the actual boost converter voltage exceeds a predetermined value, the MG ECU determines that there is a malfunction of the execution or monitoring in the boost converter voltage. The MG ECU will send information about the malfunction to the hybrid vehicle control ECU. Upon receiving this information, the hybrid vehicle control ECU will illuminate the MIL and set a DTC

MONITOR STRATEGY


Related DTCs
P0A94 (INF 442): Discrepancy between commanded and actual voltage
Required sensors / components
Boost converter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Boost converter
DTC P0A94 (INF 442) is not detected

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A94-442 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes) *1
    Generator Control Module
    P0A1B (all INF codes) *1
    Drive Motor "A" Control Module
    P0A1C (all INF codes) *1
    Drive Motor "B" Control Module
    P0A1D (all INF codes) *1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A45-669
    Drive Motor "B" Position Sensor Circuit
    P0A46-671
    Drive Motor "B" Position Sensor Circuit Range / Performance
    P0A47-670
    Drive Motor "B" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A51-174
    Drive Motor "A" Current Sensor Circuit
    P0A55-687
    Drive Motor "B" Current Sensor Circuit
    P0A60 (all INF codes) *1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes) *1
    Drive Motor "A" Phase W Current
    P0A69 (all INF codes) *1
    Drive Motor "B" Phase V Current
    P0A6C (all INF codes) *1
    Drive Motor "B" Phase W Current
    P0A72 (all INF codes) *1
    Generator Phase V Current
    P0A75 (all INF codes) *1
    Generator Phase W Current
    P0A78-266, 267, 272, 278, 280, 283, 285, 304, 305, 306, 508, 510, 523, 586
    Drive Motor "A" Inverter Performance
    P0A79-672, 690, 691, 697, 698, 701, 703
    Drive Motor "B" Inverter Performance
    P0A7A-309, 321, 323, 342, 343, 520, 522
    Generator Inverter Performance
    P0A7F-123
    Hybrid Battery Pack Deterioration
    P0A80-123
    Replace Hybrid Battery Pack
    P0A82-123, P0A84-123, P0A85-123
    Hybrid Battery Pack Cooling Fan 1
    P0A97-123, P0A99-123, P0A9A-123
    Hybrid Battery Pack Cooling Fan 2
    P0AD0-123, P0AD2-123, P0AD3-123
    Hybrid Battery Pack Cooling Fan 3
    P0A95-123
    High Voltage Fuse
    P0A94-545, 546, 551, 552, 558, 559, 561, 585, 587, 588, 589, 590
    DC / DC Converter Performance
    P0AA1 (all INF coads) *1
    Hybrid Battery Positive Contactor Circuit Stuck Closed
    P0AA4-232
    Hybrid Battery Negative Contactor Circuit Stuck Closed
    P0AA6 (all INF codes) *1
    Hybrid Battery Voltage System Isolation Fault
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE6-225
    Hybrid Battery Precharge Contactor Control Circuit Low
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P3004-132
    Power Cable Malfunction
    P3232-749
    Open or Short to B+ in Blocking of HV Gate Connection
    P3233-750
    Short to B+ in Blocking of HV Gate Connection

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
    2. Turning the power switch on (IG) with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
    3. P0A94-442 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.



B
GO TO DTC CHART (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)