ELECTRIC INVERTER COMPRESSOR > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
![]() |
When replacing the electric inverter compressor with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new electric inverter compressor before installation.
| 2. INSTALL SERVICE VALVE |
Apply sufficient compressor oil (ND-OIL 11 or equivalent) to a new O-ring and the fitting surface of the electric inverter compressor.
Install the O-ring onto the service valve.
![]() |
Install the service valve with the bolt.
| 3. INSTALL ELECTRIC INVERTER COMPRESSOR |
![]() |
Install the electric inverter compressor with the 3 bolts.
![]() |
Connect the connector <A>.
Lock the green-colored lock <B>.
Connect the connector <C>.
| 4. CONNECT SUCTION HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL 11 or equivalent) to a new O-ring and the fitting surface of the electric inverter compressor.
Install the O-ring onto the suction hose sub-assembly.
![]() |
Install the suction hose sub-assembly onto the electric inverter compressor with the bolt.
| 5. INSTALL DISCHARGE HOSE SUB-ASSEMBLY |
![]() |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL 11 or equivalent) to a new O-ring and the fitting surface of the electric inverter compressor.
Install the O-ring onto the discharge hose sub-assembly.
Install the discharge hose sub-assembly onto the electric inverter compressor with the bolt.
| 6. INSTALL BATTERY CARRIER SUB-ASSEMBLY |
![]() |
Install the 5 bolts and battery carrier.
| 7. INSTALL BATTERY |
Install the battery clamp and battery.
Connect the cable to the battery terminal.
| 8. INSTALL SERVICE PLUG GRIP |
![]() |
Wear insulated gloves, then insert the service plug.
Push down on the grip to lock.
![]() |
Close the reclining hinge cover.
![]() |
Close the rear door scuff plate LH.
| 9. CHARGE WITH REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge with refrigerant HFC-134a (R134a).

| 10. WARM UP COMPRESSOR |
Keep the A/C switch on for at least 2 minutes to warm up the compressor.
| 11. INSPECT FOR REFRIGERANT LEAK |
After recharging with refrigerant gas, inspect for a refrigerant leak using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a gas leak detector, inspect for a leak from the refrigerant lines.
![]() |
Bring the gas leak detector close to the drain hose with the detector's power off, and then turn the detector on.
If a gas leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.