Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › ELECTRIC INVERTER COMPRESSOR

ELECTRIC INVERTER COMPRESSOR > INSTALLATION

for Preparation Click here



1. ADJUST COMPRESSOR OIL


    E153516E01
  1. When replacing the electric inverter compressor with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new electric inverter compressor before installation.

    Standard:
    (Oil capacity inside the new electric inverter compressor: 120 to 135 cc (4.2 to 4.8 fl. oz.)) - (Remaining oil amount in the removed electric inverter compressor) = (Oil amount to be removed from the new compressor when replacing)

    NOTICE:
    1. When checking the compressor oil level, observe the precautions on the cooler removal/installation.
    2. If a new electric inverter compressor installed without removing some oil remaining in the pipes of the vehicle, the oil amount will be too large. This prevents heat exchange in the refrigerant cycle and caused refrigerant failure.
    3. If the volume of oil remaining in the removed electric inverter compressor is too small, check for oil leakage.
    4. Be sure to use ND-OIL 11 or equivalent for compressor oil. If any compressor oil other than ND-OIL 11 is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.



2. INSTALL SERVICE VALVE
  1. Apply sufficient compressor oil (ND-OIL 11 or equivalent) to a new O-ring and the fitting surface of the electric inverter compressor.

    Compressor oil:
    ND-OIL 11 or equivalent.

    NOTICE:
    1. Keep the O-rings and O-ring fitting surfaces clean from dirt or any foreign objects.
    2. Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

  1. Install the O-ring onto the service valve.



    E153515
  1. Install the service valve with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



3. INSTALL ELECTRIC INVERTER COMPRESSOR


    E153514E01
  1. Install the electric inverter compressor with the 3 bolts.

    Torque:
    25 N*m{ 255 kgf*cm , 18 ft.*lbf }

    NOTICE:
    Tighten the bolts in the order shown in the illustration to install the electric inverter compressor.



    E153512E01
  1. Connect the connector <A>.

    NOTICE:
    Wear insulated gloves when performing the procedures.

  1. Lock the green-colored lock <B>.

  1. Connect the connector <C>.



4. CONNECT SUCTION HOSE SUB-ASSEMBLY
  1. Remove the attached vinyl tape from the hose.

  1. Apply sufficient compressor oil (ND-OIL 11 or equivalent) to a new O-ring and the fitting surface of the electric inverter compressor.

    Compressor oil:
    ND-OIL 11 or equivalent

    NOTICE:
    1. Keep the O-rings and O-ring fitting surfaces clean from dirt or any foreign objects.
    2. Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

  1. Install the O-ring onto the suction hose sub-assembly.



    E153511
  1. Install the suction hose sub-assembly onto the electric inverter compressor with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



5. INSTALL DISCHARGE HOSE SUB-ASSEMBLY


    E153510
  1. Remove the attached vinyl tape from the hose.

  1. Apply sufficient compressor oil (ND-OIL 11 or equivalent) to a new O-ring and the fitting surface of the electric inverter compressor.

    Compressor oil:
    ND-OIL 11 or equivalent

    NOTICE:
    1. Keep the O-rings and O-ring fitting surfaces clean from dirt or any foreign objects.
    2. Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

  1. Install the O-ring onto the discharge hose sub-assembly.

  1. Install the discharge hose sub-assembly onto the electric inverter compressor with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



6. INSTALL BATTERY CARRIER SUB-ASSEMBLY


    A177162
  1. Install the 5 bolts and battery carrier.

    Torque:
    19 N*m{ 194 kgf*cm , 14 ft.*lbf }



7. INSTALL BATTERY
  1. Install the battery clamp and battery.

    Torque:
    5.4 N*m{ 55 kgf*cm , 48 in.*lbf }

  1. Connect the cable to the battery terminal.

    Torque:
    6.4 N*m{ 65 kgf*cm , 56 in.*lbf }

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



8. INSTALL SERVICE PLUG GRIP

NOTICE:
Before connecting the service plug, check that no parts and tools remain and that the high voltage terminals and connectors are connected securely.



    A176049
  1. Wear insulated gloves, then insert the service plug.

  1. Push down on the grip to lock.



    A175635
  1. Close the reclining hinge cover.

    NOTICE:
    Check that the 2 clips are securely connected to the battery carrier bracket (click sound).



    A175634
  1. Close the rear door scuff plate LH.

    NOTICE:
    Check that the 5 clips are securely connected to the battery carrier bracket (click sound).



9. CHARGE WITH REFRIGERANT
  1. Perform vacuum purging using a vacuum pump.



  1. Charge with refrigerant HFC-134a (R134a).


    E143108E02

    Standard (w/o Rear Air Conditioning System):
    550 to 650 g (19.4 to 22.9 oz.)

    Standard (w/ Rear Air Conditioning System):
    720 to 820 g (25.4 to 28.9 oz.)

    SST
    09985-20010   (09985-02130, 09985-02150, 09985-02090, 09985-02110, 09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02140)

    NOTICE:
    1. Do not turn the A/C on before charging with refrigerant. Doing so will cause the compressor to work without refrigerant, resulting in overheating of the cooler compressor.
    2. Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by quantity, not with the sight glass.
    3. Avoid using the gauge manifold set that had been used for vehicles with conventional compressor oil (ND-OIL11 or equivalent) as much as possible. This will cause compressor oil remaining in the manifold to enter the vehicle, resulting in insulation performance deterioration. A gauge manifold set that had been used 3 times or less can be reused if an appropriate one is not available.

    HINT:
    Ensure that sufficient refrigerant is available to recharge the system when using a refrigerant recovery unit. Refrigerant recovery units are not always able to recover 100% of the refrigerant from an A/C system.



10. WARM UP COMPRESSOR
  1. Keep the A/C switch on for at least 2 minutes to warm up the compressor.

    NOTICE:
    Be sure to warm up the compressor when turning the A/C on after removing and installing the cooler refrigerant lines (including the compressor), to prevent damage to the compressor.



11. INSPECT FOR REFRIGERANT LEAK
  1. After recharging with refrigerant gas, inspect for a refrigerant leak using a halogen leak detector.

  1. Carry out the test under the following conditions:

    1. Power switch off
    2. Secure good ventilation (the gas leak detector may react to volatile gases which are not refrigerant, such as evaporated gasoline and exhaust gas).
    3. Repeat the test 2 or 3 times.
    4. Make sure that there is some refrigerant remaining in the refrigeration system.
      When the compressor is off: approx. 392 to 588 kPa (4 to 6 kgf/cm2, 57 to 85 psi)



    I042222E25
  1. Using a gas leak detector, inspect for a leak from the refrigerant lines.



    N014519E06
  1. Bring the gas leak detector close to the drain hose with the detector's power off, and then turn the detector on.

    HINT:
    1. After the blower motor has stopped, let the cooling unit stand for more than 15 minutes.
    2. Bring the gas leak detector sensor under the drain hose.
    3. When bringing the gas leak detector close to the drain hose, make sure that the gas leak detector does not react to volatile gases.
      If it is not possible to avoid interference from volatile gases, the vehicle should be lifted up to allow testing.

  1. If a gas leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.

  1. Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.