Home › HYBRID SYSTEM ยท P310 › HYBRID TRANSMISSION / TRANSAXLE › OIL COOLER ASSEMBLY

OIL COOLER ASSEMBLY > INSTALLATION

for Preparation Click here



1. INSTALL WATER WITH MOTOR AND BRACKET PUMP ASSEMBLY


    C172345E01
  1. Insert the guide into the water with motor and bracket pump assembly and install the air duct with the 3 bolts.

    Torque:
    4.9 N*m{ 50 kgf*cm , 43 in.*lbf }



    A175938
  1. Install the water with motor and bracket pump assembly with the bolt and nut.

    Torque:
    6.0 N*m{ 61 kgf*cm , 53 in.*lbf }

  1. Connect the connector and 2 water hoses to the water with motor and bracket pump assembly.



    A177835
  1. Connect the 2 oil cooler hoses and 3 clamps.



2. INSTALL FRAME SIDE RAIL PLATE SUB-ASSEMBLY LH


    A108529E02
  1. Install the frame side rail plate sub-assembly with the 3 bolts and nut.

    Torque:
    Bolt (A):
    85 N*m{ 867 kgf*cm , 63 ft.*lbf }
    Bolt (B):
    32 N*m{ 326 kgf*cm , 24 ft.*lbf }
    Nut:
    32 N*m{ 326 kgf*cm , 24 ft.*lbf }



3. INSTALL FRONT BUMPER ASSEMBLY (w/o Fog Light)


    B175295
  1. Engage the 4 claws and install the front bumper assembly.

    HINT:
    Use the same procedure for the RH side and LH side.



    B172763
  1. Install the clip and 7 screws.



    B172762
  1. Install the screw and pin hold clip.

    Torque:
    3.0 N*m{ 31 kgf*cm , 27 in.*lbf }

    HINT:
    Use the same procedure for the RH side and LH side.



4. INSTALL FRONT BUMPER ASSEMBLY (w/ Fog Light)
  1. Connect each fog light connector, and then install the front bumper assembly.



    B175295
  1. Engage the 4 claws.

    HINT:
    Use the same procedure for the RH side and LH side.



    B172763
  1. Install the clip and 7 screws.



    B172762
  1. Install the screw and pin hold clip.

    Torque:
    3.0 N*m{ 31 kgf*cm , 27 in.*lbf }

    HINT:
    Use the same procedure for the RH side and LH side.



5. INSTALL RADIATOR GRILLE


    B181114
  1. Engage the 4 guides and 6 claws, and install the radiator grille.



    B181109
  1. Install the 4 clips and 2 bolts.



6. INSTALL NO. 1 ENGINE UNDER COVER
  1. Install the 6 bolts, 2 screws, 2 clips and No. 1 engine under cover.



7. ADD AND INSPECT HYBRID TRANSAXLE FLUID
  1. Add transaxle fluid.



    C173144E01
  1. Check that the fluid surface is within 5 mm (0.20 in.) from the lowest position of the inner surface of the differential filler plug opening.

    NOTICE:
    1. Keep the fluid temperature at 5°C (41°F) or higher.
    2. Stop the vehicle on a flat road.
    3. Insufficient or excessive amounts of transaxle fluid may be the cause of some trouble.

  1. Using a socket hexagon wrench 10 mm, temporarily tighten the filler plug and gasket.

  1. Enter 2WD inspection mode (Click here).

  1. After waiting for 1 minute or more, stop the engine.

  1. Using a socket hexagon wrench 10 mm, remove the filler plug and gasket.

  1. Add transaxle fluid.



    C173144E01
  1. Check that the fluid surface is within 5 mm (0.20 in.) from the lowest position of the inner surface of the differential filler plug opening.

    NOTICE:
    1. Keep the fluid temperature at 5°C (41°F) or higher.
    2. Stop the vehicle on a flat road.
    3. Recheck the transaxle fluid level after driving when exchanging fluid.
    4. Insufficient or excessive amounts of transaxle fluid may be the cause of some trouble.

  1. Check for leaks if the fluid level is low.

  1. Using a socket hexagon wrench 10 mm, install the filler plug, and a new gasket.

    Torque:
    39 N*m{ 398 kgf*cm , 29 ft.*lbf }



8. ADD COOLANT (for Inverter)

NOTICE:
  1. Do not reuse the drained coolant because it may contain foreign objects.
  2. If the vehicle is driven with air in the inverter cooling system, the following DTCs may be set.

    DTC Code
    Detection Item
    P0A01-725
    Motor Electronics Coolant Temperature Sensor Circuit Range / Performance
    P0A01-726
    Motor Electronics Coolant Temperature Sensor Circuit Range / Performance
    P0A78-284
    Drive Motor "A" Inverter Performance
    P0A7A-322
    Generator Inverter Performance
    P0A93-346
    Inverter Cooling System Performance
    P0A94-553
    DC / DC Converter Performance
    P0AEE-276
    Motor Inverter Temperature Sensor "A" Circuit Range / Performance
    P0AEE-277
    Motor Inverter Temperature Sensor "A" Circuit Range / Performance
    P3221-314
    Generator Inverter Temperature Sensor Circuit Range / Performance
    P3221-315
    Generator Inverter Temperature Sensor Circuit Range / Performance
    P3226-562
    DC/DC Boost Converter Temperature Sensor
    P3226-563
    DC/DC Boost Converter Temperature Sensor



    A179308
  1. Loosen the bleeder plug shown in the illustration and connect a hose.

    NOTICE:
    Insert one end of the hose into the reserve tank.

  1. Add coolant to the reserve tank.



    C109303E01
  1. Add coolant until the level of coolant in the hose attached to the bleeder plug reaches the same level as the FULL line of the reserve tank.

    Coolant quantity:
    3.4 liter (3.6 US qts, 3.0 Imp. qts.)

  1. When using the Techstream:

    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. On the Techstream, enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

    4. Keep the coolant at the FULL level in the reserve tank to compensate for the drop in coolant level when the air bleeds.

      Standard:
      Air bleeding from the coolant system is completed when the noise made by the water pump becomes smaller and the circulation of coolant in the reserve tank improves.

      HINT:
      Loud noise made by the water pump and poor circulation of coolant in the reserve tank indicates that there is air in the coolant system.

  1. When not using the Techstream:

    1. Turn the power switch on (READY). [*1]

    2. Turn the power switch off and add coolant to the FULL level because the coolant level drops as the air bleeds. [*2]

      NOTICE:
      1. Be sure to turn the power switch off before adding SLLC.
      2. Do not work on the components in the engine compartment while the vehicle is in the READY-on state because the engine is in intermittent operation.

    3. Repeat steps [*1] and [*2] until air bleeding from the coolant system is completed.

      Standard:
      Air bleeding from the coolant system is completed when the noise made by the water pump becomes smaller and the circulation of coolant in the reserve tank improves.

      HINT:
      Loud noise made by the water pump and poor circulation of coolant in the reserve tank indicates that there is air in the coolant system.

  1. When the air is completely bled from the coolant system, tighten the plug.



    C109304
  1. Add coolant to the FULL mark of the reserve tank.



9. INSPECT FOR COOLANT LEAK (for Inverter)
  1. Remove the reserve tank cap.

    CAUTION:
    To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.



    A175857
  1. Install the radiator cap tester.

  1. Pump the radiator cap tester to 37 kPa (0.38 kgf/ cm2, 5.4 psi), and then check that the pressure does not drop.

    HINT:
    If the pressure drops, check the hoses, radiator, water pump, inverter with converter, and hybrid vehicle transaxle assembly for leakage.

  1. Reinstall the reserve tank cap.



10. INSTALL COOL AIR INTAKE DUCT SEAL
  1. Install the cool air intake duct seal with the 11 clips.



11. INSTALL NO. 2 ENGINE ROOM SIDE COVER LH


    A173813
  1. Fit the clips and install the No. 2 engine room side cover LH.

    NOTICE:
    1. Be sure to engage the clips securely.
    2. Do not apply excessive force or do not hit the cover to engage the clips. This may cause the cover to break.