DTC B1835/58 Short in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1836/58 Open in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1837/58 Short to GND in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1838/58 Short to B+ in Front Passenger Side Curtain Shield Squib Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1835/58 |
|
|
| B1836/58 |
|
|
| B1837/58 |
|
|
| B1838/58 |
|
|

| 1.CHECK CONNECTORS |
![]() |
Turn the power switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Check that the connectors are properly connected to the curtain shield airbag assembly RH and center airbag sensor assembly.
Disconnect the connectors from the curtain shield airbag assembly RH and center airbag sensor assembly.
Check that the terminals of the connectors are not damaged.
Check that the floor wire connector (on the curtain shield airbag assembly RH side) is not damaged.
|
| ||||
| OK | |
| 2.CHECK CURTAIN SHIELD AIRBAG ASSEMBLY RH (FRONT PASSENGER SIDE CURTAIN SHIELD SQUIB) |
![]() |
Connect the connector to the center airbag sensor assembly.
Connect SST (resistance 2.1 Ω) to connector C.
Connect the negative (-) terminal cable to the battery.
Turn the power switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the power switch off.
Turn the power switch on (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 3.CHECK FLOOR WIRE (FRONT PASSENGER SIDE CURTAIN SHIELD SQUIB CIRCUIT) |
![]() |
Turn the power switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect SST from connector C.
Disconnect the floor wire from the center airbag sensor assembly.
Check for a short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| N9-1 (ICR+) - Body ground | power switch on (IG) | Below 1 V |
| N9-2 (ICR-) - Body ground | power switch on (IG) | Below 1 V |
Check for an open in the circuit.
Turn the power switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| N9-1 (ICR+) - N9-2 (ICR-) | Always | Below 1 Ω |
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| N9-1 (ICR+) - Body ground | Always | 1 MΩ or higher |
| N9-2 (ICR-) - Body ground | Always | 1 MΩ or higher |
Check for a short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| N9-1 (ICR+) - N9-2 (ICR-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Restore the released activation prevention mechanism of connector B to the original condition.
Connect the connectors to the curtain shield airbag assembly RH and the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery.
Turn the power switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the power switch off.
Turn the power switch on (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||