METER / GAUGE SYSTEM > Clock Display Circuit |

| 1.CHECK CAN COMMUNICATION SYSTEM |
Check if CAN communication DTC is output (Click here).
| Result | Proceed to |
| CAN communication DTC is not output. | A |
| CAN communication DTC is output. | B |
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (CLOCK ASSEMBLY - COMBINATION METER) |
![]() |
Disconnect the E11 and E1 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E11-3 (HSI+) - E1-17 (LCL-) | Always | Below 1 Ω |
| E11-10 (DATA) - E1-37 (MDAT) | Always | Below 1 Ω |
| E11-11 (SYNC) - E1-38 (SYNC) | Always | Below 1 Ω |
| E11-3 (HSI+) - Body ground | Always | 10 kΩ or higher |
| E11-10 (DATA) - Body ground | Always | 10 kΩ or higher |
| E11-11 (SYNC) - Body ground | Always | 10 kΩ or higher |
| E11-16 (SGND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 3.INSPECT COMBINATION METER ASSEMBLY |
![]() |
Reconnect the E1 combination meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E11-3 (HSI+) - Body ground | Power switch on (READY) | Pulse generation |
| E11-10 (DATA) - Body ground | Power switch on (READY) | Pulse generation |
| E11-11 (SYNC) - Body ground | Power switch on (READY) | 4 to 6 V |
|
| ||||
| OK | ||
| ||