Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

DTC    B1500    Fuel Sender Open Detected

for Preparation Click here


DESCRIPTION

This DTC is output when the combination meter assembly detects a fuel sender gauge malfunction via the direct line.

DTC No.
DTC Detection Condition
Trouble Area
B1500
When either of the following conditions is detected:
  1. IG voltage is 10.5 V or more
  2. Fuel sender gauge operation malfunction
  1. Harness or connector
  2. Combination meter assembly
  3. Fuel sender gauge assembly

WIRING DIAGRAM


E156126E13


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (FUEL INPUT)
  1. Connect the Techstream to the DLC3.

  1. Turn the engine switch on (IG).

  1. Turn the tester on.

  1. Enter following menus: Body / Combination Meter / Data List.

  1. Check the values by referring to the table below.

    Combination Meter: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Fuel Input
    Fuel input signal/Min.: 0, Max.: 127.5
    Fuel gauge indicates (E): 7.5 (L)
    Fuel gauge indicates (1/2): 35.0 (L)
    Fuel gauge indicates (F): 62.9 (L)
    -

    Result:

    Result
    Proceed to
    Fuel level data can be displayed on the Techstream and DTC B1500 is output.
    A
    Fuel level data cannot be displayed on the Techstream.
    B



B
Go to step 2
A

REPLACE COMBINATION METER ASSEMBLY (Click here)  

2.INSPECT COMBINATION METER ASSEMBLY


    E146920E13
  1. Disconnect the E1 connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E1-19 (FE) - E1-34 (FR)
    Always
    13.5 to 414.5 Ω



NG
Go to step 3
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)  

3.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SENDER GAUGE ASSEMBLY)
E152442E04
  1. Disconnect the fuel sender gauge assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E1-34 (FR) - 2
    Always
    Below 1 Ω
    E1-34 (FE) - Body ground
    Always
    10 kΩ or higher
    E1-19 (FE) - 1
    Always
    Below 1 Ω
    E1-19 (FE) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.INSPECT FUEL SENDER GAUGE ASSEMBLY
E146925E01
  1. Remove the fuel sender gauge assembly (Click here).

  1. Check that the float moves smoothly between E and F.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Float level is F (upper)
    3.0 to 5.0 Ω
    1 - 2
    Float level is between F (upper) and E (lower)
    3.0 to 111.0 Ω (Gradually changes)
    1 - 2
    Float level is E (lower)
    109.0 to 111.0 Ω



NG
REPLACE FUEL SENDER GAUGE ASSEMBLY (for 2GR-FE) (Click here)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)