Home › BODY ELECTRICAL › METER › COMBINATION METER

COMBINATION METER > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait for 90 seconds after disconnecting the terminal to prevent airbag deployment (Click here).

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



2. REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY


    E152488
  1. Disengage the 4 claws and 4 clips, and remove the instrument cluster finish panel assembly.



3. REMOVE COMBINATION METER ASSEMBLY


    E152487
  1. Remove the 4 screws.

  1. Disconnect the connector and remove the combination meter assembly.