Home › HYBRID SYSTEM · P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0ADF-229    Hybrid Battery Negative Contactor Circuit Stuck Open

DTC    P0AE0-228    Hybrid Battery Negative Contactor Circuit Stuck Closed

for Preparation Click here


DESCRIPTION

Refer to the description for DTC P0AE6-225 (Click here).

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0ADF
229
Short to GND in the SMR3 (CON3) circuit
  1. Wire harness or connector
  2. HV relay assembly
  3. Hybrid vehicle control ECU
P0AE0
228
Open or +B short in SMR3 (CON3) circuit

WIRING DIAGRAM

  1. See the wiring diagram of P0AE6-225 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HV RELAY ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector D36 from the hybrid vehicle control ECU.

  1. Disconnect connector z20 from the HV relay assembly.

  1. Turn the power switch on (IG).



    A175138E06
  1. Measure the voltage according to the value(s) in the table below.

    HINT:
    Turning the power switch on (IG) with the service plug grip removed causes an interlock switch system DTC (P0A0D-350) to be set.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D36-1 (CON3) - Body ground
    Power switch on (IG)
    Below 1 V

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    D36-1 (CON3) - z20-2 (CON3)
    Power switch off
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    D36-1 (CON3) or z20-2 (CON3) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2.CHECK HV RELAY ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the HV relay assembly from the vehicle (Click here).



    A108054E13
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    z31-1 - j3-1
    Auxiliary battery voltage is applied between terminals z20-2 (CON3) and z20-4 (GND)
    Below 1 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    z20-2 (CON3) - z20-4 (GND)
    -31 to 176°F (-35 to 80°C)
    20 to 60 Ω



NG
REPLACE HV RELAY ASSEMBLY (Click here)
OK

REPLACE HYBRID VEHICLE CONTROL ECU (Click here)