DTC P0606 ECM / PCM Processor |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0606 | Hybrid vehicle control ECU main CPU error | Hybrid vehicle control ECU |
| Related DTC | P0606: ECM range check |
| Required Sensors/Components (Main) | ECM |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | Within 1 second |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not present | None |
| CPU reset | Occurred |
| 1.READ OUTPUT DTC (DTC P0606) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Clear the DTCs (Click here).
Turn the power switch off and turn the Techstream off.
Disconnect the Techstream.
Disconnect the cable from the auxiliary battery negative (-) terminal and wait for 1 minute.
Connect the cable to the auxiliary battery negative (-) terminal.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Select the following menu items: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
| No output | A |
| P0606 | B |
|
| ||||
| A | ||
| ||