SECURITY HORN ASSEMBLY > REMOVAL |
| 1. PRECAUTION |
Check for DTCs (Click here).
| 2. READ DTC OUTPUT |
Check for DTCs.
| 3. REMOVE FRONT WIPER ARM AND BLADE ASSEMBLY LH |
![]() |
Remove the nut, and the front wiper arm and blade assembly LH.
| 4. REMOVE FRONT WIPER ARM AND BLADE ASSEMBLY RH |
![]() |
Remove the nut, and the front wiper arm and blade assembly RH.
| 5. REMOVE HOOD TO COWL TOP SEAL |
![]() |
Disengage the 8 clips and remove the hood to cowl top seal.
| 6. REMOVE COWL TOP VENTILATOR LOUVER SUB-ASSEMBLY |
![]() |
Disengage the 2 claws and disconnect the front fender to cowl side seal LH.
![]() |
Disengage the 2 claws and disconnect the front fender to cowl side seal RH.
Remove the 2 clips.

Disengage the 20 claws and remove the cowl top ventilator louver sub-assembly.
| 7. REMOVE WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY |
![]() |
Disconnect the connector.
Remove the 4 bolts, and the windshield wiper motor and link assembly.
| 8. REMOVE OUTER COWL TOP PANEL SUB-ASSEMBLY |
![]() |
Disengage the 4 clamps and separate the wiper wire harness from the outer cowl top panel sub-assembly.
![]() |
Remove the 8 bolts, 6 nuts, and the outer cowl top panel sub-assembly.
| 9. REMOVE NO. 2 ENGINE ROOM SIDE COVER LH |
![]() |
Remove the engine room side cover.
| 10. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 11. REMOVE SERVICE PLUG GRIP |
![]() |
Remove the 5 clips and door scuff plate LH.
![]() |
Remove the 2 clips and reclining hinge cover.
![]() |
Wear insulated glove and remove the service plug grip, after sliding up the lever of the service plug grip.
| 12. DRAIN COOLANT (for Inverter) |
Remove the inverter reserve tank cap.
![]() |
Using a hexagon wrench (10 mm), remove the drain plug indicated in the illustration and drain the coolant.
Install the plug with a new gasket.
| 13. REMOVE COOL AIR INTAKE DUCT SEAL |
Remove the 11 clips and cool air intake duct seal.
| 14. REMOVE AIR CLEANER CAP SUB-ASSEMBLY |
![]() |
Remove the 2 bolts, 4 clamps and air cleaner cap sub-assembly.
Remove the air cleaner filter element from the air cleaner case.
| 15. REMOVE AIR CLEANER CASE SUB-ASSEMBLY |
![]() |
Separate the No. 1 ventilation hose.
![]() |
Disconnect the intake air flow meter connector.
Disconnect the 2 wire harness clamps from the air cleaner case sub-assembly.
![]() |
Remove the 5 bolts from the air cleaner case sub-assembly.
![]() |
Loosen the hose clamp and separate the No. 1 air cleaner hose.
Remove the air cleaner case sub-assembly.
| 16. DISCONNECT NO. 1 CIRCUIT BREAKER SENSOR |
![]() |
Move the outer section to the wire harness side as illustrated, then disconnect the No. 1 circuit breaker sensor.
| 17. REMOVE INVERTER RESERVE TANK SUB-ASSEMBLY |
![]() |
Remove the 2 bolts and inverter reserve tank sub-assembly.
![]() |
Slide the 2 clamps, and disconnect the 2 water hoses from the inverter reserve tank sub-assembly.
| 18. DISCONNECT NO. 2 ENGINE ROOM WIRE |
Remove the relay block cover.
![]() |
Disconnect the clamp, and release the engine room relay block assembly.
![]() |
Disconnect the 4 claws, and disconnect the No. 2 relay block cover.
![]() |
Remove the nut from the No. 2 engine room wire.
Release the 2 claws, and disconnect the No. 2 engine room wire.
Disconnect the clamp.
| 19. DISCONNECT WATER HOSE |
![]() |
Slide the clamp, and disconnect the water hose from the inverter with converter assembly.
| 20. REMOVE INVERTER COVER |
![]() |
Remove the bolt and interlock bracket.
![]() |
Insulate the removed terminal with insulating tape.
![]() |
Remove the 12 bolts and inverter cover.
| 21. INSPECT TERMINAL VOLTAGE |
![]() |
Using the voltmeter, measure the voltage between the terminals of the 2 phase connectors (N-P).
| 22. SEPARATE NO. 4 ENGINE WIRE |
![]() |
Remove the bolt, and disconnect the No. 4 engine wire from the inverter with converter assembly.
Disconnect the connector, clamps and grommet, and separate the No. 4 engine wire from the inverter with converter assembly.
| 23. DISCONNECT HIGH VOLTAGE CABLE OF FRONT MOTOR |
![]() |
Remove the 5 bolts, and disconnect the high voltage cables of the motor from the inverter with converter assembly.
![]() |
Remove the 5 bolts, and disconnect the high voltage cables of the generator (MG1) from the inverter with converter assembly.
| 24. DISCONNECT MG ECU CONNECTOR |
![]() |
Disconnect the 2 connectors and 2 grommets from the inverter with converter assembly.
| 25. DISCONNECT NO. 3 FRAME WIRE |
![]() |
Remove the 5 bolts, and disconnect the No. 3 frame wire (high voltage cables of the rear motor (MGR)) from the inverter with converter assembly.
![]() |
Remove the bolt and lift the lever to disconnect the No. 3 frame wire from the inverter with converter assembly.
| 26. INSTALL INVERTER COVER |
![]() |
Temporarily install the inverter cover with the 2 bolts to prevent any foreign objects or waterdrops from entering the inverter with converter assembly.
| 27. SEPARATE ENGINE ROOM RELAY BLOCK ASSEMBLY |
![]() |
Disconnect the clamp, and release the engine room relay block assembly.
| 28. REMOVE NO. 4 INVERTER BRACKET |
![]() |
Remove the 2 bolts and No. 4 inverter bracket.
| 29. REMOVE INVERTER WITH CONVERTER ASSEMBLY |
![]() |
Disconnect the coolant hose from the inverter with converter assembly. Put a piece of cloth in the pipe and in the disconnected hose or cover the pipe and hose with plastic bags as shown in the illustration, in order to prevent coolant from spilling around the inverter with converter assembly.
![]() |
Remove the 2 nuts, bolt and inverter with converter assembly.
| 30. REMOVE SECURITY HORN ASSEMBLY |
![]() |
Remove the bolt.
Disconnect the connector and remove the security horn assembly.