DTC P0AA1-233 Hybrid Battery Positive Contactor Circuit Stuck Closed |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0AA1 | 233 | SMR1, SMR2. or SMR3 on the HV battery positive and negative sides stuck closed | HV relay assembly |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-523 is not output | A |
| P0A78-523 is output | B |
|
| ||||
| A | |
| 2.CHECK HV RELAY ASSEMBLY |
Turn the power switch off.
![]() |
Remove the service plug grip (Click here).
Measure the resistance according to the value(s) in the table below. (Inspection of SMR1 and SMR2)
| Tester Connection | Switch Condition | Specified Condition |
| z30-1 - j2-1 | Power switch off | 10 kΩ or higher |
![]() |
Measure the resistance according to the value(s) in the table below. (Inspection of SMR3)
| Tester Connection | Switch Condition | Specified Condition |
| z31-1 - j3-1 | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||