This circuit provides power to the headlight cleaner control relay.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the A41 headlight cleaner control relay connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A41-3 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A41-4 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 4F instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A41-3 (IG) - 4F-11 | Always | Below 1 Ω |
| A41-3 (IG) or 4F-11 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG