1. PRECAUTION (w/ Smart Entry and Start System)
If the main body ECU (multiplex network body ECU) is replaced, refer to Service Bulletin.
89221
2.INSTALL MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
Make sure that no foreign matter gets on the connecting surfaces.
Do not touch the main body ECU (multiplex network body ECU) connector.
Set the main body ECU (multiplex network body ECU) to the position where the guide of the main body ECU (multiplex network body ECU) contacts the housing sidewall of the instrument panel junction block assembly as shown in the illustration.
| *A | for LHD | *B | for RHD |
| *a | 20° or more | *b | Housing Sidewall |
Make sure to keep the angle at 20° or more as shown in the illustration.
Slide the main body ECU (multiplex network body ECU) along the housing sidewall as shown in the illustration and engage the 2 guides.
| *A | for LHD | *B | for RHD |
| *a | Housing Sidewall | - | - |
While keeping the main body ECU (multiplex network body ECU) in contact with side A of the instrument panel junction block assembly (axis of rotation), lower it as shown in the illustration.
| *A | for LHD | *B | for RHD |
| *a | Side A | - | - |
Press the push area until the claw engages to install the main body ECU (multiplex network body ECU).
| *A | for LHD | *B | for RHD |
| *1 | Instrument Panel Junction Block Assembly | *2 | Main Body ECU (Multiplex Network Body ECU) |
| *a | Push Area | - | - |
Make sure to press only the push area.
Confirm the engagement of the main body ECU (multiplex network body ECU) and instrument panel junction block assembly by listening for the click sound of the lock engaging.
If a click sound cannot be heard, visually check the engagement of the lock. The engagement can also be confirmed if the main body ECU (multiplex network body ECU) and instrument panel junction block assembly are flush.
3.INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY WITH MAIN BODY ECU (for LHD)
Connect the connector and push down the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Slide the connector lock to engage the claw as shown in the illustration.
Connect the connector and push down the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Engage the clamp as shown in the illustration.
Install the instrument panel junction block assembly with main body ECU with the 2 nuts.
Engage the clamp.
Connect the connector and raise the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Connect the connector and raise the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Connect each connector.
4.INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY WITH MAIN BODY ECU (for RHD)
Connect the connector and push down the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Slide the connector lock to engage the claw as shown in the illustration.
Connect the connector and push down the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Engage the guide and claw to connect the connector holder as shown in the illustration.
Engage the clamp as shown in the illustration.
|
Bolt |
|
Nut |
Install the instrument panel junction block assembly with main body ECU with the 2 bolts and nut.
Connect the connector and raise the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Connect the connector and raise the lock lever to engage the claw and lock the connector as shown in the illustration.
Be sure to connect the connector securely.
Connect each connector.
55045
5.INSTALL LOWER INSTRUMENT PANEL FINISH PANEL SUB-ASSEMBLY (for LHD)
53601
6.CONNECT HOOD LOCK CONTROL LEVER SUB-ASSEMBLY (for LHD)
55606
7.INSTALL NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (for LHD)
55303B
8.INSTALL LOWER INSTRUMENT PANEL SUB-ASSEMBLY (for RHD)
55607
9.INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (for RHD)
55436A
10.INSTALL INSTRUMENT PANEL FINISH PANEL END LH
11.INSTALL FRONT DOOR OPENING TRIM WEATHERSTRIP LH
62112A
12.INSTALL COWL SIDE TRIM SUB-ASSEMBLY LH
67914
13.INSTALL FRONT DOOR SCUFF PLATE LH
14.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION