The main power source for the main body ECU (multiplex network body ECU) is supplied via the door control battery.
If the main body ECU (multiplex network body ECU) is replaced, refer to Service Bulletin.*
*: w/ Smart Entry and Start System
Inspect the fuses for circuits related to this system before performing the following procedure.
After performing the following inspection, perform Initialization.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Disconnect the F88 door control battery connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F88-5 (BATB) - Body ground | Always | 11 to 14 V |
| F88-4 (BECU) - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F88-2 (GND1) - Body ground | Always | Below 1 Ω |
| F88-10 (GND2) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 4D instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F88-3 (EDOR) - 4D-23 | Always | Below 1 Ω |
| F88-3 (EDOR) or 4D-23 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the F88 door control battery connector.
Turn the ignition switch off.
Remove the MPX-B NO. 1 fuse and leave the vehicle as is for 50 minutes.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F88-3 (EDOR) - Body ground | Ignition switch OFF | Below 2 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the F88 door control battery connector.
Install the MPX-B NO. 1 fuse.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F88-3 (EDOR) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Remove the main body ECU (multiplex network body ECU).
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| MB-31 (BECU) - 4D-23 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG