Home › Power Source / Network › NETWORKING › NETWORK GATEWAY ECU › from 2016.11
RM3160E _57 Power Source / Network _019704 NETWORKING _0095664 NETWORK GATEWAY ECU A

NETWORKING  NETWORK GATEWAY ECU  INSTALLATION  


CAUTION / NOTICE / HINT

PROCEDURE

Hide 89111 1.INSTALL CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)

a.

Engage the 2 claws to install the central gateway ECU (network gateway ECU).


Hide 82877 2.INSTALL ECU INTEGRATION BOX RH (for LHD)

Hide 82878 3.INSTALL ECU INTEGRATION BOX LH (for RHD)

Hide 4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION