In this circuit, the cooler compressor assembly (compressor solenoid) receives a refrigerant compression demand signal from the air conditioning amplifier assembly.
Based on this signal, the cooler compressor assembly (compressor solenoid) changes the amount of compressor output.
In this circuit, the compressor assembly with pulley (compressor solenoid) receives a refrigerant compression demand signal from the air conditioning amplifier assembly.
Based on this signal, the compressor assembly with pulley (compressor solenoid) changes the amount of compressor output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1451/51 | Compressor Solenoid Circuit | Open or short in compressor solenoid circuit | ·
Cooler compressor assembly (compressor solenoid)*1 ·
Compressor assembly with pulley (compressor solenoid)*2 ·
Harness or connector between air conditioning amplifier assembly and cooler compressor assembly (compressor solenoid)*1 ·
Harness or connector between air conditioning amplifier assembly and compressor assembly with pulley (compressor solenoid)*2 ·
Air conditioning amplifier assembly |
- |
*1: for 2GR-FKS
*2: for 1AR-FE
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 2GR-FKS | A |
| for 1AR-FE | B |
A
B
| *a | Component without harness connected
(Cooler Compressor Assembly (Compressor Solenoid)) |
Disconnect the C16 cooler compressor assembly (compressor solenoid) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-1 (SOL-) - C16-2 (SOL+) | 25°C (77°F) | 10.1 to 11.1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-1 (SOL-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F80 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-2 (SOL+) - F80-2 (SOL+) | Always | Below 1 Ω |
| C16-2 (SOL+) or F80-2 (SOL+) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to Problem Symptoms Table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
A
B
C
| *a | Component without harness connected
(Compressor Assembly with Pulley (Compressor Solenoid)) |
Disconnect the C16 compressor assembly with pulley (compressor solenoid) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-1 (SOL-) - C16-2 (SOL+) | 25°C (77°F) | 10.1 to 11.1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-1 (SOL-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F80 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-2 (SOL+) - F80-2 (SOL+) | Always | Below 1 Ω |
| C16-2 (SOL+) or F80-2 (SOL+) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to Problem Symptoms Table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
A
B
C