In this circuit, the cooler compressor assembly (compressor solenoid) receives a refrigerant compression demand signal from the air conditioning amplifier assembly.
Based on this signal, the cooler compressor assembly (compressor solenoid) changes the amount of compressor output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1451 | Compressor Solenoid Circuit | Open or short in compressor solenoid circuit | ·
Cooler compressor assembly (compressor solenoid) ·
Harness or connector between air conditioning amplifier assembly and cooler compressor assembly (compressor solenoid) ·
Air conditioning amplifier assembly |
- |
| *a | Component without harness connected
(Cooler Compressor Assembly (Compressor Solenoid)) |
Disconnect the C16 cooler compressor assembly (compressor solenoid) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-1 (SOL-) - C16-2 (SOL+) | 25°C (77°F) | 10.1 to 11.1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-1 (SOL-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F80 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C16-2 (SOL+) - F80-2 (SOL+) | Always | Below 1 Ω |
| C16-2 (SOL+) or F80-2 (SOL+) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to Problem Symptoms Table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |