| All functions of the air conditioning system do not operate
|
IG power source circuit
|
|
| Back-up power source circuit
|
|
| Air conditioning control panel circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower operation
|
Blower motor circuit
|
|
| Air conditioning control panel circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower control
|
Blower motor circuit
|
|
| Air conditioning control panel circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: Insufficient air flow
|
Blower motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: Cooling effectiveness is poor
|
Refrigerant shortage check using the GTS
|
|
| Refrigerant volume
|
-
|
| Refrigerant pressure
|
|
| Cooler expansion valve
|
|
| Cooler compressor assembly
|
|
| Air conditioning amplifier assembly
|
|
| Clean the cooling fans
|
|
| Temperature control: No cool air comes out
|
Refrigerant shortage check using the GTS
|
|
| Refrigerant volume
|
-
|
| Refrigerant pressure
|
|
| Air conditioner pressure sensor circuit
|
|
| Air conditioning control panel circuit
|
|
| Air mix damper control servo motor circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Cooler expansion valve
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (Air mix)
|
|
| Air conditioning harness assembly
|
|
| Cooler compressor assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: No warm air comes out
|
Air conditioning control panel circuit
|
|
| Air mix damper control servo motor circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (Air mix)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: Output air is warmer or cooler than the set temperature or response is slow
|
Refrigerant shortage check using the GTS
|
|
| Refrigerant volume
|
-
|
| Refrigerant pressure
|
|
| Compressor solenoid circuit
|
|
| Automatic light control sensor
|
|
| Ambient temperature sensor circuit
|
|
| Air conditioning control panel circuit
|
|
| Air mix damper control servo motor circuit
|
|
| Air inlet damper control servo motor circuit
|
|
| Heater radiator unit sub-assembly
|
|
| Cooler expansion valve
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (Air mix)
|
|
| Blower damper servo sub-assembly (Air inlet)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: No temperature control (only MAX COLD or MAX HOT)
|
Air conditioning control panel circuit
|
|
| Air mix damper control servo motor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Automatic light control sensor
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (Air mix)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: Output air temperature is different between left and right registers (the set temperature is the same for both)
|
Refrigerant shortage check using the GTS
|
|
| Refrigerant volume
|
-
|
| Refrigerant pressure
|
|
| Air mix damper control servo motor circuit
|
|
| Automatic light control sensor
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (Air mix)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| No air inlet control
|
Air conditioning control panel circuit
|
|
| Air inlet damper control servo motor circuit
|
|
| Blower damper servo sub-assembly (Air inlet)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| No air flow mode control
|
Air conditioning control panel circuit
|
|
| Air outlet damper control servo motor circuit
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (Air outlet)
|
|
| Air conditioning harness assembly
|
|
| Air conditioning amplifier assembly
|
|
| Diagnostic Trouble Codes (DTCs) are not recorded. Set mode is cleared when the ignition switch is turned off
|
Back-up power source circuit
|
|
| Air conditioning amplifier assembly
|
|