This circuit is the power source circuit for the combination meter assembly. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.
Inspect the fuses of circuits related to this system before performing the following procedure.
Disconnect the F126 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F126-19 (E2) - Body ground | Always | Below 1 Ω |
| F126-31 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F126-21 (IG+) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |
| F126-1 (B) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |