Home › Power Source / Network › 2GR-FKS BATTERY / CHARGING › GENERATOR › from 2016.11
RM3160E _57 Power Source / Network _060166 2GR-FKS BATTERY / CHARGING _0303645 GENERATOR A

2GR-FKS BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 16361A 4.REMOVE FAN & GENERATOR V BELT

Hide 27020 5.REMOVE GENERATOR ASSEMBLY

a.
A386443

Open the terminal cap.


b.

Remove the nut and disconnect the wire harness from terminal B.


c.

Disconnect the generator assembly connector.


d.

Disconnect the magnetic clutch connector.


e.

Disengage the 2 wire harness clamps.


f.
A386444

Type A:

i.

Remove the 2 bolts and generator assembly bracket.



g.

Type B:

i.
A386445

Remove the bolt, nut and generator assembly bracket.



h.
A229061

Remove the 2 bolts and generator assembly.


i.
A386448

Remove the bolt and wire harness clamp bracket.