UA80E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P280714  Pressure Control Solenoid "G" Circuit Short to Ground or Open  


DESCRIPTION

Refer to DTC P280712.

Click hereDrivetrain>UA80E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>P280712

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P280714 Pressure Control Solenoid "G" Circuit Short to Ground or Open 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
1.

Driving so that gear changes occur

2.

Solenoid (SL4) valve circuit is open or short to ground

3.

1 second

4.

1-trip detection logic


·

Solenoid (SL4) valve

·

Transmission wire

·

Harness and connector

·

ECM


Comes on DTC stored SAE Code:
P2814

MONITOR DESCRIPTION

This DTC indicates an open or short to ground in the solenoid (SL4) valve circuit. The ECM commands gear shifts by turning the solenoid valves on or off. When there is an open or short in any solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores a DTC.

The ECM performs the fail-safe function and turns the other normal solenoid valves on or off. In the case of an open or short circuit, the ECM stops sending current to the open or shorted solenoid.

CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>UA80E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION


HINT:

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.



PROCEDURE

1.CHECK HARNESS AND TRANSMISSION WIRE (TRANSMISSION WIRE (SOLENOID (SL4) VALVE) - ECM)
a.

Disconnect the C1 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C1-14 (SL4+) - C1-15 (SL4-) 20°C (68°F) 5.0 to 5.6 Ω
C1-14 (SL4+) or C1-15 (SL4-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.REPLACE ECM

NG

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
2.REPLACE ECM

Result:
Proceed to
NEXT



NEXT

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.

Disconnect the C85 transmission wire connector.


b.

Disconnect the C1 ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C85-15 (SL4+) - C1-14 (SL4+) Always Below 1 Ω
C85-14 (SL4-) - C1-15 (SL4-) Always Below 1 Ω
C85-15 (SL4+) or C1-14 (SL4+) - Body ground and other terminals Always 10 kΩ or higher
C85-14 (SL4-) or C1-15 (SL4-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

4.INSPECT SOLENOID (SL4) VALVE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)

4.INSPECT SOLENOID (SL4) VALVE
a.
C197715C76
1.75,1 2.198,0.417 true 1.5,1.01 1.042,0.427 true 1.75,2.979 2.198,2.385 true 1.479,2.979 1.021,2.385 true 0.073,0.083 0.469,0.344 0.396,0.26 10 false *a 2.25,0.24 2.521,0.5 0.271,0.26 10 false 1 0.896,0.25 1.156,0.5 0.26,0.25 10 false 2 2.281,2.198 2.521,2.479 0.24,0.281 10 false 1 0.875,2.219 1.156,2.49 0.281,0.271 10 false 2 1.865,3.948 2.271,4.271 0.406,0.323 10 false (+) 1.219,3.948 1.594,4.25 0.375,0.302 10 false (-)
*a Component without harness connected
(Solenoid (SL4) Valve)


Remove the solenoid (SL4) valve.

Click hereDrivetrain>UA80E (AUTOMATIC TRANSMISSION / TRANSAXLE)>VALVE BODY ASSEMBLY>DISASSEMBLY


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid (SL4) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Connect a positive (+) lead from the battery with a 21 W bulb to terminal 1 and a negative (-) lead to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.

OK:

Valve moves and makes an operating sound.



Result:
Proceed to
OK
NG



OK

NG