Home › Power Source / Network › 1AR-FE BATTERY / CHARGING › GENERATOR › from 2018.09
RM3160E _57 Power Source / Network _019679 1AR-FE BATTERY / CHARGING _0105677 GENERATOR A

1AR-FE BATTERY / CHARGING  GENERATOR  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.

Install the generator assembly with the 2 bolts.

Torque:
52 N*m (530 kgf*cm, 38 ft.*lbf)


b.

Install the wire harness clamp bracket with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.

Connect the generator assembly connector.


d.

Connect the wire harness to terminal B and install the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


e.

Close the terminal cap.


Hide 3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION