The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during battery voltage sensor removal/installation are shown below.
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
for 2WD: Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>PRECAUTION
for 4WD/AWD: Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD)>PRECAUTION
To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
The type of battery voltage sensor to be used varies depending on the vehicle model.
If the wrong type of battery voltage sensor is installed, the ignition switch cannot be turned on (READY).
When replacing the battery voltage sensor, always replace it with a new one.
After installing the battery voltage sensor, perform the following to check that the ignition switch can be turned on (READY).
Turn the ignition switch to on (READY).
Turn the ignition switch off and wait for 30 seconds or more.
Turn the ignition switch to on (READY) again.
After the ignition switch is turned off, the radio and display receiver assembly or the radio receiver assembly records various types of memory and settings. As a result, after turning the ignition switch off, make sure to wait at least 120 seconds before disconnecting the cable from the negative (-) auxiliary battery terminal.
1.REMOVE HV BATTERY JUNCTION BLOCK ASSEMBLY
82161
2.DISCONNECT FLOOR WIRE
Be sure to wear insulated gloves.
Disconnect the electric vehicle battery plug assembly connector.
Disengage the 3 clamps to disconnect the floor wire.
G920Q
3.REMOVE NO. 1 HYBRID BATTERY SHIELD SUB-ASSEMBLY
4.REMOVE NO. 6 HV BATTERY CARRIER BRACKET
Be sure to wear insulated gloves.
Disengage the clamp.
Remove the 4 nuts and No. 6 HV battery carrier bracket.
89892A
5.REMOVE BATTERY VOLTAGE SENSOR
Be sure to wear insulated gloves.
Disconnect the 3 battery voltage sensor connectors.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Remove the 2 nuts and battery voltage sensor from the HV battery.
If the battery voltage sensor has been struck or dropped, replace it.