Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › BLIND SPOT MONITOR SYSTEM
RM37A0E _56 Audio / Visual / Telematics _086880 PARK ASSIST / MONITORING _0420015 BLIND SPOT MONITOR SYSTEM C

PARK ASSIST / MONITORING  BLIND SPOT MONITOR SYSTEM  C1ABE  Short to GND or Open in Buzzer  


DESCRIPTION

DTC C1ABE is stored when the blind spot monitor sensor RH (slave) detects a short to ground or open in the RCTA buzzer (blind spot monitor buzzer) circuit.

DTC No. Detection Item DTC Detection Condition Trouble Area
C1ABE Short to GND or Open in Buzzer
Both of the following conditions are met:
·

The blind spot monitor system is on

·

The blind spot monitor sensor is not sounding the buzzer but the buzzer receives voltage below a specified level for a specified period of time.


·

Blind spot monitor sensor RH (slave)

·

RCTA buzzer (blind spot monitor buzzer)

·

Wire harness or connector



WIRING DIAGRAM

E406228E02
0.167,1.01 1.573,1.208 1.406,0.198 10 false from IG1-NO. 1 Relay 3.5,1 3.792,1.198 0.292,0.198 10 false BZP 3.229,1.302 3.573,1.5 0.344,0.198 10 false M45 3.229,1.479 4.802,1.875 1.573,0.396 10 false RCTA Buzzer (Blind Spot Monitor Buzzer) 5.615,1.927 5.906,2.125 0.292,0.198 10 false M2 5.615,2.083 6.813,2.448 1.198,0.365 10 false Blind Spot Monitor Sensor RH (Slave) 4.333,1.01 4.667,1.208 0.333,0.198 10 false BZN 3.333,0.906 3.479,1.083 0.146,0.177 10 false 1 5.646,1.021 5.979,1.219 0.333,0.198 10 false BUZ 5.469,0.917 5.615,1.094 0.146,0.177 10 false 3 4.677,0.917 4.823,1.094 0.146,0.177 10 false 2 2.021,1.177 3.042,1.375 1.021,0.198 10 false ECU-IG1 NO. 4

CAUTION / NOTICE / HINT

NOTICE:
·

When checking for DTCs, make sure that the blind spot monitor system is turned on.

·

Inspect the fuses for circuits related to this system before performing the following procedure.



PROCEDURE

1.CHECK DTC
a.

Turn the ignition switch off.


b.

Turn the ignition switch to ON.


c.

Recheck for DTCs and check if the same DTC is output again.

Body Electrical > Blind Spot Monitor Slave > Trouble Codes
50001 314
OK:

No DTCs are output.



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (RCTA BUZZER - AUXILIARY BATTERY AND BLIND SPOT MONITOR SENSOR RH (SLAVE))
2.CHECK HARNESS AND CONNECTOR (RCTA BUZZER - AUXILIARY BATTERY AND BLIND SPOT MONITOR SENSOR RH (SLAVE))
a.

Disconnect the M45 RCTA buzzer (blind spot monitor buzzer) connector.


b.

Disconnect the M2 blind spot monitor sensor RH (slave) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M45-2 (BZN) - M2-3 (BUZ) Always Below 1 Ω
M45-2 (BZN) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.REPLACE RCTA BUZZER (BLIND SPOT MONITOR BUZZER)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.REPLACE RCTA BUZZER (BLIND SPOT MONITOR BUZZER)

NEXT

4.CHECK DTC
4.CHECK DTC
a.

Clear the DTCs.

Body Electrical > Blind Spot Monitor Slave > Clear DTCs
50002 314

b.

Recheck for DTCs and check if the same DTC is output again.

Body Electrical > Blind Spot Monitor Slave > Trouble Codes
50001 314
OK:

No DTCs are output.



Result:
Proceed to
OK
NG



OK

END

NG