The rear evaporator temp. sensor (No. 2 air conditioning harness assembly) is installed on the evaporator in the rear cooling unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the rear evaporator temp. sensor (No. 2 air conditioning harness assembly) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the rear evaporator temp. sensor (No. 2 air conditioning harness assembly) and reads voltage changes as the resistance of the rear evaporator temp. sensor (No. 2 air conditioning harness assembly) changes. This sensor is used for frost prevention.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1417 | Evaporator Temperature Circuit | Open or short in rear evaporator temperature sensor circuit | ·
Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) ·
Harness or connector between rear evaporator temp. sensor (No. 2 air conditioning harness assembly) and air conditioning amplifier assembly ·
Air conditioning amplifier assembly |
Memorized
(4 sec. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evap Temp Sensor (Rear) | Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator (rear) temperature displayed | Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) circuit malfunction
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Tester Display |
|---|
| Evap Temp Sensor (Rear) |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REAR EVAPORATOR TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H65 air conditioning amplifier assembly connector.
Disconnect the M15 rear evaporator temp. sensor (No. 2 air conditioning harness assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H65-11 (TEC) - M15-8 (+) | Always | Below 1 Ω |
| H65-15 (SG-9) - M15-7 (-) | Always | Below 1 Ω |
| H65-11 (TEC) or M15-8 (+) - Body ground | Always | 10 kΩ or higher |
| H65-15 (SG-9) or M15-7 (-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG