MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU monitors the motor generator control ECU (MG ECU).
The cause of this malfunction may be the following:
Motor generator control ECU (MG ECU) malfunction
The hybrid vehicle control ECU monitors the motor generator control ECU (MG ECU) and stores this DTC when it detects a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation | The motor generator control ECU (MG ECU) value received by the hybrid vehicle control ECU exceeds the threshold for a certain period of time.
(1 trip detection logic) |
·
Inverter with converter assembly ·
IGCT relay ·
IGCT-IG fuse |
Comes on | Master Warning:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD)>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
With ignition switch ON and wait for 2 minutes or more.
If the vehicle has returned to normal, it can be driven after turning the ignition switch to ON (READY).
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Check the connection of the negative (-) and positive (+) auxiliary battery terminals.
The terminals are connected securely and there is no contact problem.
If performing a simulation test, turn the ignition switch to ON and shake the wire harnesses vertically and horizontally before checking for DTCs.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the installation condition of the ground wires OA.
The ground wires OA are securely installed.
If performing a simulation test, turn the ignition switch to ON and shake the wire harnesses vertically and horizontally before checking for DTCs.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and NO. 5 Floor Junction Block Assembly |
| *2 | IGCT-IG Fuse |
Remove the IGCT-IG fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT-IG fuse | Always | Below 1 Ω |
Reinstall the IGCT-IG fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the IGCT relay for improper installation.
The relay is installed securely.
If performing a simulation test, turn the ignition switch to ON and gently vibrate the IGCT relay with a finger before checking for DTCs.
| *1 | No. 5 Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT Relay |
Remove the IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | IGCT Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the IGCT relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for DTCs.
Check the DTCs that were output when the vehicle was brought to the workshop.
| Result | Proceed to |
|---|---|
| P0A1B94 only is output. | A |
| DTCs except P0A1B94 are output. | B |
Turn the ignition switch off.
A
B
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD)>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Turn the ignition switch to ON and wait for 2 minutes or more.
Turn the ignition switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs are output. | A |
| P0A1B94 only is output. | B |
| DTCs except P0A1B94 are output. | C |
Turn the ignition switch off.
A
B
C