Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER
RM37A0E _51 Engine / Hybrid System _086850 HYBRID / BATTERY CONTROL _0419997 INVERTER WITH CONVERTER A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link

*1: Learning can also be performed using the GTS.

Click here(Click here)

Auxiliary battery terminal is disconnected/reconnected Perform steering sensor zero point calibration Lane control system (Click here)
Parking Support Brake System*1
Pre-collision System
Memorize steering angle neutral point Parking Assist Monitor System (Click here)
Panoramic View Monitor System (Click here)
Initialize back door lock Power Door Lock Control System (Click here)
Reset back door close position Power Back Door System (Click here)
Replacement of inverter with converter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


for 2WD:
(Click here)
for 4WD/AWD:
(Click here)
Replacement of ECM Perform Vehicle Identification Number (VIN) registration DTC is output (Click here)

CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.

for 2WD: Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>PRECAUTION

for 4WD/AWD: Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD)>PRECAUTION

·
A340358

To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.



NOTICE:

After the ignition switch is turned off, the radio and display receiver assembly or the radio receiver assembly records various types of memory and settings. As a result, after turning the ignition switch off, make sure to wait at least 120 seconds before disconnecting the cable from the negative (-) auxiliary battery terminal.


PROCEDURE

Hide 3.DRAIN COOLANT (for Inverter)

Hide 12601B 4.REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY

Hide 53295E 5.REMOVE COOL AIR INTAKE DUCT SEAL

Hide 17750A 6.REMOVE INLET AIR CLEANER ASSEMBLY

a.
A451913

Remove the 2 bolts and inlet air cleaner assembly.


Hide 7.REMOVE AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE

a.
A451914

Disconnect the mass air flow meter sub-assembly connector.


b.

Disengage the wire harness clamp.


c.
A451915C01
1.219,3.792 0.844,3.229 0.844,3.229 1.688,3.74 true 1.521,3.979 1.646,4.104 1.646,4.104 1.802,4.104 false 0.667,3.115 0.979,3.281 0.313,0.167 10 false *a 1.823,4.01 2.135,4.167 0.313,0.156 10 false *b
*a Grommet
*b Pin


Slide the clip and disconnect the No. 2 ventilation hose from the cylinder head cover sub-assembly.


d.

Loosen the hose clamp and disconnect the air cleaner assembly with air cleaner hose from the throttle body with motor assembly.


e.

Disengage the 2 grommets and pin to remove the air cleaner assembly with air cleaner hose.


Hide 82111 9.DISCONNECT ENGINE ROOM MAIN WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A451917

Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Insulate the disconnected terminals with insulating tape.




b.
A451918

Remove the bolt.


c.

Disengage the clamp and disconnect the engine room main wire.


Hide 10.REMOVE CONNECTOR COVER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.
A451919C01
2.594,1.042 2.813,1.229 0.219,0.188 10 true *a 2.25,0.594 2.469,0.76 0.219,0.167 10 true *b
*a Bolt (A)
*b Bolt (B)


Remove the bolt (B).


b.

Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




Hide 11.CHECK TERMINAL VOLTAGE

CAUTION:

Be sure to wear insulated gloves.


a.
A451920

Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

Standard Voltage:

0 V


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


HINT:

Use a measuring range of DC 750 V or more on the voltmeter.



Hide 12.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.
A451921

Temporarily install the connector cover assembly to the inverter with converter assembly.


b.

Using a T25 "TORX" socket wrench, install the bolt.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




Hide 821H1 13.DISCONNECT FLOOR UNDER WIRE

CAUTION:

Be sure to wear insulated gloves.


a.

for 4WD/AWD:

i.
A451922C01
2.24,2.875 2.177,3.146 2.177,3.146 1.792,3.146 true 1.635,3.052 1.948,3.25 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the 2 bolts and disconnect the HV floor under wire from the inverter with converter assembly.

NOTICE:
·

Do not damage the terminals, interlock connector or inverter with converter assembly during disconnection.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Although the connector may feel loose, this is not due to a malfunction.





b.
A451923

Remove the 2 nuts and disconnect the HV floor under wire from the inverter with converter assembly.


c.
A451924C01
0.885,0.615 1.115,0.219 1.115,0.219 1.375,0.219 true 1.417,0.125 1.729,0.323 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the bolt and disconnect the HV floor under wire from the inverter with converter assembly.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.




Hide 821H2 14.DISCONNECT HV AIR CONDITIONING WIRE

CAUTION:

Be sure to wear insulated gloves.


a.
A451925C01
0.896,0.625 1.219,0.344 1.219,0.344 1.385,0.344 true 1.406,0.26 1.719,0.417 0.313,0.156 10 false *a
*a Waterproof Seal


Remove the 2 bolts.


b.

Disengage the clamp and disconnect the HV air conditioning wire from the inverter with converter assembly.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.




Hide 15.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A451926

Remove the nut and wire harness clamp bracket.


Hide 82121 16.DISCONNECT ENGINE WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A460085

Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Insulate the disconnected terminals with insulating tape.




b.
A460086N01
1.979,0.115 2.135,0.313 0.156,0.198 10 true A 1.938,1.208 2.094,1.406 0.156,0.198 10 true A 1.479,1.729 1.635,1.927 0.156,0.198 10 true A 1.406,0.365 1.563,0.563 0.156,0.198 10 true B 0.688,2.938 0.844,3.135 0.156,0.198 10 true B

Disengage the 3 clamps (A) and disconnect the No. 1 fuel vapor feed hose.


c.

Remove the bolt.


d.

Disengage the 2 clamps (B).


e.
A455467C01
2.417,0.406 2.625,0.583 0.208,0.177 10 true *a 2.792,1.104 2.99,1.271 0.198,0.167 10 true *b 2.25,1.469 2.458,1.635 0.208,0.167 10 true *c
*a Generator Temperature Sensor Connector
*b Resolver (Transmission Fluid Temperature Sensor) Connector
*c Shift Lever Position Sensor Connector


Disconnect the generator temperature sensor connector, resolver (transmission fluid temperature sensor) connector and shift lever position sensor connector and disengage the clamp.

NOTICE:
C440115

After disconnecting the engine wire, cover the connector of the generator temperature sensor, resolver (transmission fluid temperature sensor) and shift lever position sensor with tape (non-residue type) or equivalent to prevent the entry of foreign matter or water.



f.
A455468

Disengage the 2 clamps.


g.
A455469

Remove the bolt.


h.
A455470

Remove the bolt.


i.
A455471

Disengage the 2 claws and open the engine wire terminal cover.


j.
A455472

Remove the nut.


k.

Disengage the 2 clamps and disconnect the engine wire from the inverter with converter assembly.


Hide 33820B 17.DISCONNECT TRANSMISSION CONTROL CABLE ASSEMBLY

a.
C426967

Remove the nut and disconnect the transmission control cable assembly from the control shaft lever.


b.
C426968

Using a screwdriver, disengage the 4 claws and disconnect the transmission control cable assembly with the clip from the No. 1 transmission control cable bracket.


c.
C377870

Using a screwdriver, disengage the 2 claws and remove the clip from the transmission control cable assembly.


d.
A455473

Remove the 2 bolts and disconnect the transmission control cable assembly from the inverter with converter assembly.


Hide G9225K 18.DISCONNECT NO. 1 INVERTER COOLING HOSE

a.
A455474

Slide the clip and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide G9228A 19.DISCONNECT NO. 4 INVERTER COOLING HOSE

a.
A455475

Slide the clip and disconnect the No. 4 inverter cooling hose from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide G9221 20.REMOVE INVERTER COVER

CAUTION:

Be sure to wear insulated gloves.


a.
A455477C01
1.49,2.573 1.865,2.094 1.865,2.094 1.469,2.406 true 1.563,2.719 1.688,2.969 1.688,2.969 1.927,2.969 true 2.875,2.542 2.833,3.073 2.833,3.073 2.604,3.073 false 0.615,2.688 0.667,2.135 0.667,2.135 0.875,2.135 false 1.948,2.885 2.26,3.083 0.313,0.198 10 false *a 1.885,1.979 2.198,2.177 0.313,0.198 10 false *b 2.49,3 2.646,3.198 0.156,0.198 10 false A 0.927,2.063 1.083,2.26 0.156,0.198 10 false A
*a Interlock
*b Waterproof Seal


Remove the 2 bolts and inverter cover from the inverter with converter assembly.

NOTICE:
·

Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.

·

Do not touch the waterproof seal of the inverter cover.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

When removing the inverter cover, do not pull the areas (A) as they may deform.

·

Make sure that the interlock is installed to the inverter cover.

·
A376320C02
2.167,2.115 2.656,1.635 2.656,1.635 2.031,1.24 false 1.031,0.313 1.302,0.313 1.302,0.313 1.823,0.781 true 0.865,0.208 1.177,0.406 0.313,0.198 10 false *a 2.698,1.542 3.01,1.74 0.313,0.198 10 false *1
*1 Inverter Cover
*a Screw


Do not remove or excessively tighten the screw of the inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.

·

Do not damage the terminals, interlock connector or inverter with converter assembly during removal.



HINT:
A455478C01
1.135,1.75 0.979,1.75 0.979,1.75 0.854,1.375 true 1.167,1.656 1.406,1.854 0.24,0.198 10 true *a
*a Protective Tape


If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.



Hide G1148 21.DISCONNECT MOTOR CABLE

CAUTION:

Be sure to wear insulated gloves.


a.
A455479

Using an insulated tool, remove the 6 bolts.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.




b.
A455480C01
1.01,0.219 1.208,0.219 1.208,0.219 1.656,0.469 true 0.833,0.115 1.146,0.271 0.313,0.156 10 false *a
*a Waterproof Seal


Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

After disconnecting the motor cable, wrap it with a plastic bag or equivalent to protect it.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·
A460087

To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.




Hide 22.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A455476

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


Hide G9200 23.REMOVE INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.

Remove the 5 bolts, 2 nuts and inverter with converter assembly.

A460088

NOTICE:
·

When removing the inverter with converter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.



HINT:

Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.



Hide G9214 24.REMOVE NO. 1 INVERTER BRACKET

NOTICE:
A455483C01
0.76,1.052 1.792,1.917 1.792,1.917 2.219,1.073 true 0.135,0.125 0.448,0.281 0.313,0.156 10 false *a 1.74,1.927 2.052,2.083 0.313,0.156 10 false *b
*a Bottom of Inverter with Converter Assembly
*b Support


Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.


a.
A460089C01
2.177,1.813 2.833,1.906 2.833,1.906 2.594,1.625 true 2.885,1.854 3.198,2.01 0.313,0.156 10 false *a
*a Wooden Block


Set the inverter with converter assembly on wooden blocks.


b.

Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.


Hide G9215 25.REMOVE NO. 2 INVERTER BRACKET

a.
A460090C01
2.302,1.885 2.958,1.979 2.958,1.979 2.719,1.698 true 2.979,1.885 3.292,2.042 0.313,0.156 10 false *a
*a Wooden Block


Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.


Hide 26.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A460091

Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.


b.
A460092

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


c.
A460093

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


d.
A460094

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.